Heat Loss from a Ventilated Clothed Body
The heat flux from the surface of a hot body in an air stream was measured with a simple apparatus that obviates the need for a wind tunnel. Measurements were made with the body covered with a range of polyester nonwoven fabrics. The results were analyzed on the basis of Take-uchi's theory.
Gespeichert in:
Veröffentlicht in: | Textile research journal 1990-07, Vol.60 (7), p.378-383 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 383 |
---|---|
container_issue | 7 |
container_start_page | 378 |
container_title | Textile research journal |
container_volume | 60 |
creator | Lamb, George E.R. Yoneda, Morihiro |
description | The heat flux from the surface of a hot body in an air stream was measured with a simple apparatus that obviates the need for a wind tunnel. Measurements were made with the body covered with a range of polyester nonwoven fabrics. The results were analyzed on the basis of Take-uchi's theory. |
doi_str_mv | 10.1177/004051759006000702 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1283696169</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_004051759006000702</sage_id><sourcerecordid>1283696169</sourcerecordid><originalsourceid>FETCH-LOGICAL-c318t-53d2db00a234dd379545819f9a56b22ed19c222445ccba8df85f519a79576f223</originalsourceid><addsrcrecordid>eNp9kD1PwzAURS0EEqXwB5gydgl9dvw5QgUUKRILsFpObEOqtC52MvTf4yhsSEx3OefqvYvQLYY7jIVYA1BgWDAFwAFAADlDCywoL4Wg8hwtJqCciEt0ldIuM1IKuUCrrTNDUYeUCh_DvjDFhzsMXW8GZ4tNH4avnA_Bnq7RhTd9cje_uUTvT49vm21Zvz6_bO7rsq2wHEpWWWIbAEMqam0lFKNMYuWVYbwhxFmsWkIIpaxtGyOtl8wzrEwGBfeEVEu0mnuPMXyPLg1636XW9b05uDAmjYmsuOKYq4ySGW1jvj86r4-x25t40hj0NIv-O0uW1rOUzKfTuzDGQ37nP-MH8ztfLQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1283696169</pqid></control><display><type>article</type><title>Heat Loss from a Ventilated Clothed Body</title><source>SAGE Complete</source><creator>Lamb, George E.R. ; Yoneda, Morihiro</creator><creatorcontrib>Lamb, George E.R. ; Yoneda, Morihiro</creatorcontrib><description>The heat flux from the surface of a hot body in an air stream was measured with a simple apparatus that obviates the need for a wind tunnel. Measurements were made with the body covered with a range of polyester nonwoven fabrics. The results were analyzed on the basis of Take-uchi's theory.</description><identifier>ISSN: 0040-5175</identifier><identifier>EISSN: 1746-7748</identifier><identifier>DOI: 10.1177/004051759006000702</identifier><language>eng</language><publisher>Thousand Oaks, CA: SAGE Publications</publisher><subject>Covering ; Heat flux ; Heat loss ; Heat transfer ; Polyester resins ; Streams ; Textiles ; Wind tunnels</subject><ispartof>Textile research journal, 1990-07, Vol.60 (7), p.378-383</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c318t-53d2db00a234dd379545819f9a56b22ed19c222445ccba8df85f519a79576f223</citedby><cites>FETCH-LOGICAL-c318t-53d2db00a234dd379545819f9a56b22ed19c222445ccba8df85f519a79576f223</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/004051759006000702$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/004051759006000702$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,776,780,21799,27903,27904,43600,43601</link.rule.ids></links><search><creatorcontrib>Lamb, George E.R.</creatorcontrib><creatorcontrib>Yoneda, Morihiro</creatorcontrib><title>Heat Loss from a Ventilated Clothed Body</title><title>Textile research journal</title><description>The heat flux from the surface of a hot body in an air stream was measured with a simple apparatus that obviates the need for a wind tunnel. Measurements were made with the body covered with a range of polyester nonwoven fabrics. The results were analyzed on the basis of Take-uchi's theory.</description><subject>Covering</subject><subject>Heat flux</subject><subject>Heat loss</subject><subject>Heat transfer</subject><subject>Polyester resins</subject><subject>Streams</subject><subject>Textiles</subject><subject>Wind tunnels</subject><issn>0040-5175</issn><issn>1746-7748</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><recordid>eNp9kD1PwzAURS0EEqXwB5gydgl9dvw5QgUUKRILsFpObEOqtC52MvTf4yhsSEx3OefqvYvQLYY7jIVYA1BgWDAFwAFAADlDCywoL4Wg8hwtJqCciEt0ldIuM1IKuUCrrTNDUYeUCh_DvjDFhzsMXW8GZ4tNH4avnA_Bnq7RhTd9cje_uUTvT49vm21Zvz6_bO7rsq2wHEpWWWIbAEMqam0lFKNMYuWVYbwhxFmsWkIIpaxtGyOtl8wzrEwGBfeEVEu0mnuPMXyPLg1636XW9b05uDAmjYmsuOKYq4ySGW1jvj86r4-x25t40hj0NIv-O0uW1rOUzKfTuzDGQ37nP-MH8ztfLQ</recordid><startdate>19900701</startdate><enddate>19900701</enddate><creator>Lamb, George E.R.</creator><creator>Yoneda, Morihiro</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>19900701</creationdate><title>Heat Loss from a Ventilated Clothed Body</title><author>Lamb, George E.R. ; Yoneda, Morihiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c318t-53d2db00a234dd379545819f9a56b22ed19c222445ccba8df85f519a79576f223</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Covering</topic><topic>Heat flux</topic><topic>Heat loss</topic><topic>Heat transfer</topic><topic>Polyester resins</topic><topic>Streams</topic><topic>Textiles</topic><topic>Wind tunnels</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lamb, George E.R.</creatorcontrib><creatorcontrib>Yoneda, Morihiro</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Textile research journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lamb, George E.R.</au><au>Yoneda, Morihiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Heat Loss from a Ventilated Clothed Body</atitle><jtitle>Textile research journal</jtitle><date>1990-07-01</date><risdate>1990</risdate><volume>60</volume><issue>7</issue><spage>378</spage><epage>383</epage><pages>378-383</pages><issn>0040-5175</issn><eissn>1746-7748</eissn><abstract>The heat flux from the surface of a hot body in an air stream was measured with a simple apparatus that obviates the need for a wind tunnel. Measurements were made with the body covered with a range of polyester nonwoven fabrics. The results were analyzed on the basis of Take-uchi's theory.</abstract><cop>Thousand Oaks, CA</cop><pub>SAGE Publications</pub><doi>10.1177/004051759006000702</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0040-5175 |
ispartof | Textile research journal, 1990-07, Vol.60 (7), p.378-383 |
issn | 0040-5175 1746-7748 |
language | eng |
recordid | cdi_proquest_miscellaneous_1283696169 |
source | SAGE Complete |
subjects | Covering Heat flux Heat loss Heat transfer Polyester resins Streams Textiles Wind tunnels |
title | Heat Loss from a Ventilated Clothed Body |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T05%3A42%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Heat%20Loss%20from%20a%20Ventilated%20Clothed%20Body&rft.jtitle=Textile%20research%20journal&rft.au=Lamb,%20George%20E.R.&rft.date=1990-07-01&rft.volume=60&rft.issue=7&rft.spage=378&rft.epage=383&rft.pages=378-383&rft.issn=0040-5175&rft.eissn=1746-7748&rft_id=info:doi/10.1177/004051759006000702&rft_dat=%3Cproquest_cross%3E1283696169%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1283696169&rft_id=info:pmid/&rft_sage_id=10.1177_004051759006000702&rfr_iscdi=true |