Lead complications, device infections, and clinical outcomes in the first year after implantation of cardiac resynchronization therapy-defibrillator and cardiac resynchronization therapy-pacemaker

The decision to implant a cardiac resynchronization therapy (CRT) system with (defibrillator, CRT-D) or without (pacemaker, CRT-P) cardioverter defibrillator should weigh its benefits and risks. This study examined the (i) incidence of loss of capture and infectious complications and (ii) 1-year cli...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Europace (London, England) England), 2013-01, Vol.15 (1), p.71-76
Hauptverfasser: Schuchert, Andreas, Muto, Carmine, Maounis, Themistoklis, Frank, Robert, Boulogne, Eric, Polauck, Alexander, Padeletti, Luigi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The decision to implant a cardiac resynchronization therapy (CRT) system with (defibrillator, CRT-D) or without (pacemaker, CRT-P) cardioverter defibrillator should weigh its benefits and risks. This study examined the (i) incidence of loss of capture and infectious complications and (ii) 1-year clinical outcomes of 402 CRT-D and CRT-P recipients enrolled in the MASCOT study. The indications for CRT-D or CRT-P were posed by the implanting physicians. All (i) losses of atrial and right and left ventricular capture, (ii) system-related infections, and (iii) clinical outcomes, including hospitalizations for worsening heart failure (HF) and deaths from all causes, were recorded up to 1 year of follow-up. Cardiac resynchronization therapy-defibrillator was implanted in 228 (57%) and CRT-P in 174 (43%) patients. The incidence of loss of capture was greater in CRT-D with 21 patients (9.2%) than in CRT-P with 6 patient (3.5%) recipients (P = 0.01), while the infection rates were 1.3% (3 patients) and 1.2% (2 patients), respectively (ns). In the CRT-D group, 42 of 228 patients (18.4%) died or were hospitalized for HF, compared with 38 of 174 patients (21.8%) in the CRT-P group (ns). In the CRT-D group, 23 patients (10.1%) were hospitalized for worsening HF and 20 (8.8%) patients died, vs. 22 (12.6%) and 19 (10.9%) patients, respectively, in the CRT-P group (ns for both comparisons). Cardiac resynchronization therapy-defibrillator was implanted in 57% of candidates for CRT. Within 1 year after device implant, the incidence of loss of capture at any lead was nearly three-fold greater among CRT-D than among CRT-P recipients. System-related infections were infrequent and clinical outcomes were similar in both groups.
ISSN:1099-5129
1532-2092