Revitalizing a Vital Sign: Improving Detection of Tachypnea at Primary Triage
Study objective This study evaluates the accuracy of emergency department (ED) triage respiratory rate measurement using the usual care method and a new electronic respiratory rate sensor (BioHarness, Zephyr Technology Corp.), both compared to a criterion standard measurement. Methods This is a cros...
Gespeichert in:
Veröffentlicht in: | Annals of emergency medicine 2013-01, Vol.61 (1), p.37-43 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Study objective This study evaluates the accuracy of emergency department (ED) triage respiratory rate measurement using the usual care method and a new electronic respiratory rate sensor (BioHarness, Zephyr Technology Corp.), both compared to a criterion standard measurement. Methods This is a cross-sectional study with convenience sampling conducted in an urban academic adult ED, including 3 separate respiratory rate measurements performed at ED triage: usual care measurement, electronic BioHarness measurement, and criterion standard measurement. The criterion standard measurement used was defined by the World Health Organization as manual observation or auscultation of respirations for 60 seconds. The resultant usual care and BioHarness measurements were compared with the criterion standard, evaluating accuracy (sensitivity and specificity) for detecting tachypnea, as well as potential systematic biases of usual care and BioHarness measurements using a Bland Altman analysis. Results Of 191 analyzed patients, 44 presented with tachypnea (>20 breaths/min). Relative to criterion standard measurement, usual care measurement had a sensitivity of 23% (95% confidence interval [CI] 12% to 37%) and specificity of 99% (95% CI 97% to 100%) for tachypnea, whereas BioHarness had a sensitivity of 91% (95% CI 80% to 97%) and specificity of 97% (95% CI 93% to 99%) for tachypnea. Usual care measurements clustered around respiratory rates of 16 and 18 breaths/min (n=144), with poor agreement with criterion standard measurement. Conversely, BioHarness measurement closely tracked criterion standard values over the range of respiratory rates. Conclusion Current methods of respiratory rate measurement at ED triage are inaccurate. A new electronic respiratory rate sensor, BioHarness, has significantly greater sensitivity for detecting tachypnea versus usual care method of measurement. |
---|---|
ISSN: | 0196-0644 1097-6760 |
DOI: | 10.1016/j.annemergmed.2012.05.030 |