The use of isothermal titration calorimetry and molecular dynamics to show variability in DNA transfection performance

The mechanism causing variability in DNA transfection efficacy for low-molecular-weight pDMAEMA (poly(2-(dimethylamino)ethyl methacrylate) and pDMAEMA-b-pHEMA (poly(2-(dimethyl amino)ethylmethacrylate)-block-poly(2-hydroxyl methacrylate)) has so far remained unclear, apart from the evidence of benef...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta biomaterialia 2013-02, Vol.9 (2), p.4994-5002
Hauptverfasser: Samsonova, Olga, Glinca, Serghei, Biela, Adam, Pfeiffer, Christian, Dayyoub, Eyas, Sahin, Damla, Klebe, Gerhard, Kissel, Thomas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The mechanism causing variability in DNA transfection efficacy for low-molecular-weight pDMAEMA (poly(2-(dimethylamino)ethyl methacrylate) and pDMAEMA-b-pHEMA (poly(2-(dimethyl amino)ethylmethacrylate)-block-poly(2-hydroxyl methacrylate)) has so far remained unclear, apart from the evidence of beneficial effects of the pHEMA grafting. This study has explicitly characterized the electrostatically driven self-assembly process of linear polymethacrylate polymers with DNA-generating nanocarriers for efficient gene transfection. Isothermal titration calorimetry (ITC) showed clear differences in binding-heat profiles of homo-polycationic and pHEMA grafted polymers with DNA. Polyethylene imine, a branched polycationic polymer of 25kDa with high transfection potential that has previously been successfully used in transfection experiments, demonstrated a heat flow profile that was partly identical to pDMAEMA-b-pHEMA. Computational molecular dynamics (MD) simulated the folding process of polymer in water from a linear to a coiled state: homo-pDMAEMA and pHEMA grafts reduced their overall positive charge accessibility upon folding, down to 45% and 63%, respectively. The homo-pDMAEMA formed the globular conformation more preferably than pHEMA grafts, thus impeding electrostatic interaction with DNA. These findings substantiate the known disadvantage of low-molecular-weight linear polymers compared to higher-molecular-weight polymers in transfection performance; here we have disclosed the ability of a non-cationic chain elongation to be beneficial for the self-assembly process. The combination of MD and ITC has proved to be a suitable approach for carrier–payload interaction studies and may be used to predict the efficacy of a polymer as a nanocarrier from the flexibility of its structure.
ISSN:1742-7061
1878-7568