Novel on-line sequential preconcentration system of Cr(III) and Cr(VI) hyphenated with flame atomic absorption spectrometry exploiting sorbents based on chemically modified silica

In the present study, a flow injection system using dual mini-columns, SiO2/Al2O3/TiO2 and silica gel functionalized with [3-(2-aminoethylamino)propyl] trimethoxysilane (SiO2/AAPTMS) for the sequential preconcentration of Cr(III) and Cr(VI), respectively, from water samples with FAAS detection was p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2012-10, Vol.100, p.71-79
Hauptverfasser: Tarley, César R.T., Lima, Giovana F., Nascimento, Danielle R., Assis, Alan R.S., Ribeiro, Emerson S., Diniz, Kristiany M., Bezerra, Marcos A., Segatelli, Mariana G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In the present study, a flow injection system using dual mini-columns, SiO2/Al2O3/TiO2 and silica gel functionalized with [3-(2-aminoethylamino)propyl] trimethoxysilane (SiO2/AAPTMS) for the sequential preconcentration of Cr(III) and Cr(VI), respectively, from water samples with FAAS detection was proposed. A two-level full factorial design (24) and desirability function were employed for the optimization of variables related to the system performance. The detection limits of 0.66 and 0.27μgL−1 for Cr(III) and Cr(IV), respectively, were obtained under the optimized preconcentration conditions (flow rate of 7.0mLmin−1), pH 5.0, buffer concentration (acetate buffer) of 0.01molL−1, and eluent (2.5molL−1 HCl) flow rate of 5.0mLmin−1. The other parameters including preconcentration factor (PF), consumptive index (CI), and concentration efficiency (CE) were found to be 17.62/32.98, 1.13/0.6mL, and 6.2/11.54min−1 for Cr(III)/Cr(VI), respectively. The developed method was applied to the Cr(III) and Cr(VI) determination in water samples [tap, lake and mineral water, artificial saliva and parenteral solutions (physiological serum, water for injection, and glucose physiological solution)]. The method accuracy was checked by the analysis of standard reference materials (trace elements in water). ► SiO2/Al2O3/TiO2 and SiO2/AAPTMS was used for speciation of Cr(III) and Cr(VI). ► Different kinds of water and parenteral samples at the same pH were analyzed. ► Some shortcomings commonly observed in previous publication we avoided in method. ► Detection limits for Cr(III) (0.66μgL−1) and Cr(VI) (0.27μgL−1) were obtained.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2012.08.023