Preanalytic variables of thrombin generation: towards a standard procedure and validation of the method

Background: Thrombin generation assays are sensitive methods for assessment of the overall clotting potential of plasma, but, despite their common use in thrombosis research, standardization of preanalytic conditions is lacking. In order to set up a standardized protocol, we analyzed different prean...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of thrombosis and haemostasis 2012-12, Vol.10 (12), p.2544-2554
Hauptverfasser: LOEFFEN, R., KLEINEGRIS, M.‐C. F., LOUBELE, S. T. B. G., PLUIJMEN, P. H. M., FENS, D., van OERLE, R., ten CATE, H., SPRONK, H. M. H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: Thrombin generation assays are sensitive methods for assessment of the overall clotting potential of plasma, but, despite their common use in thrombosis research, standardization of preanalytic conditions is lacking. In order to set up a standardized protocol, we analyzed different preanalytic variables and validated the calibrated automated thrombogram method. Methods and Results: Thrombin generation was assessed with 0, 1 and 5 pm tissue factor (TF). Variations in thrombin generation were mostly attributable to the type of collection tube, mainly because of variations in contact activation. The collection tube also determined the influence of other preanalytic variables on thrombin generation, e.g. the need for a discard tube, the storage of whole blood, and the centrifugation method. Regarding the collection system, blood drawn through intravenous catheters or butterfly needles showed significantly more hemolysis than blood obtained with venipuncture using conventional needles. The results showed that a discard tube is still needed for thrombin generation measurements. After blood collection, whole blood is best centrifuged immediately, to prevent activation or degradation of coagulation proteins, and a second centrifugation step at 10 000 × g is recommended. After thawing, plasma is best analyzed immediately, as storage resulted in thrombin generation results outside the 10% range of the reference sample. On the basis of these results, we set up an in‐house standardized protocol, which was used for validation, resulting in coefficients of variations of
ISSN:1538-7933
1538-7836
1538-7836
DOI:10.1111/jth.12012