Assessment of the impact of rivaroxaban on coagulation assays: Laboratory recommendations for the monitoring of rivaroxaban and review of the literature

Abstract Introduction Rivaroxaban does not require monitoring nor frequent dose adjustment. However, searching for the optimal dose in the individual patient may be useful in some situations. Aim To determine which coagulation assay could be used to assess the impact of rivaroxaban on haemostasis an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Thrombosis research 2012-12, Vol.130 (6), p.956-966
Hauptverfasser: Douxfils, Jonathan, Mullier, François, Loosen, Claire, Chatelain, Christian, Chatelain, Bernard, Dogné, Jean-Michel
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Introduction Rivaroxaban does not require monitoring nor frequent dose adjustment. However, searching for the optimal dose in the individual patient may be useful in some situations. Aim To determine which coagulation assay could be used to assess the impact of rivaroxaban on haemostasis and provide guidelines for the interpretation of routine lab tests. Materials Rivaroxaban was spiked at concentrations ranging from 11 to 1090 ng/mL in plateletpoor plasma. A large panel of coagulation assays was tested. Results A concentration dependent prolongation of aPTT, PT, dPT, PiCT was observed. PT and dPT were the most sensitive chronometric assays but results varied depending on the reagent (Triniclot PT Excel S > Recombiplastin 2 G > Neoplastin R > Neoplastin CI + > Triniclot PT Excel > Triniclot PT HTF > Innovin). FXa chromogenic assays showed the highest sensitivity. In TGA, Cmax was the most sensitive parameter with the tissue factor induced pathway. Rivaroxaban interferes on haemostasis diagnostic tests such the measurement of clotting factors, fibrinogen, antithrombin, proteins C and S, activated protein-C resistance and Xa-based chomogenic assays. Conclusions PT may be used as screening test to assess the risk of bleedings. A more specific and sensitive assay such as Biophen DiXaI using calibrators should be used to confirm the concentration of rivaroxaban. We also propose cut-off associated with a bleeding or thrombosis risk based on pharmacokinetic studies. Standardization of the time between the last intake of rivaroxaban and the sampling is mandatory.
ISSN:0049-3848
1879-2472
DOI:10.1016/j.thromres.2012.09.004