The value of 3.0Tesla diffusion-weighted MRI for pelvic nodal staging in patients with early stage cervical cancer

The purpose of this study is to investigate the diagnostic accuracy of 3.0Tesla (3T) diffusion-weighted magnetic resonance imaging (MRI) in addition to conventional MRI for the detection of lymphadenopathy in patients with early stage cervical cancer compared to histopathological evaluation of the s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of cancer (1990) 2012-12, Vol.48 (18), p.3414-3421
Hauptverfasser: Klerkx, W.M., Veldhuis, W.B., Spijkerboer, A.M., van den Bosch, M.A., Mali, W.P., Heintz, A.P., Bipat, S., Sie-Go, D.M., van der Velden, J., Schreuder, H.W., Stoker, J., Peeters, P.H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The purpose of this study is to investigate the diagnostic accuracy of 3.0Tesla (3T) diffusion-weighted magnetic resonance imaging (MRI) in addition to conventional MRI for the detection of lymphadenopathy in patients with early stage cervical cancer compared to histopathological evaluation of the systematically removed pelvic lymph nodes as reference standard. 68 fédération internationale de gynécologie obstétrique (FIGO) stage Ia2 to IIb cervical cancer patients were included. Sensitivity and specificity rates for two experienced observers were computed for the detection of lymphatic metastasis. Reproducibility of conventional MRI was tested by kappa statistics. The variables included in the analysis were: size of the long axis, short axis, ratio short to long axis and apparent diffusion coefficient (ADC). Nine patients had 15 positive pelvic nodes at histopathological examination. The sensitivity and specificity of lymphatic metastasis detection by predefined conventional MRI characteristics was 33% (95% Confidence Interval (CI) 3–64) and 83% (95% CI 74–93) on patient level, and 33% (95% CI 7–60) and 97% (95% CI 95–99) on regional level respectively for observer 1. For observer 2 the sensitivity was 33% (95% CI 3–64) and the specificity 93% (95% CI 87–100) on patient level, and 25% (95% CI 1–50) and 98% (95% CI 97–100) on regional level, respectively. The kappa-value for reproducibility of metastasis detection on regional level was 0.50. The short axis diameter showed the highest diagnostic accuracy (area under the curve (AUC)=0.81 95% CI 0.70–0.91); ADC did not improve diagnostic accuracy (AUC=0.83 95% CI 0.73–0.93). Diffusion-weighted MRI did not result in additional diagnostic value compared to conventional MRI.
ISSN:0959-8049
1879-0852
DOI:10.1016/j.ejca.2012.06.022