Technical Note: Evaluation of between-sample memory effects in the analysis of delta super(2)H and delta super(18)O of water samples measured by laser spectroscopes
This study evaluated between-sample memory in isotopic measurements of delta super(2)H and delta super(18)O in water samples by laser spectroscopy. Ten isotopically depleted water samples spanning a broad range of oxygen and hydrogen isotopic compositions were measured by three generations of off-ax...
Gespeichert in:
Veröffentlicht in: | Hydrology and earth system sciences 2012-10, Vol.16 (10), p.3925-3933 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study evaluated between-sample memory in isotopic measurements of delta super(2)H and delta super(18)O in water samples by laser spectroscopy. Ten isotopically depleted water samples spanning a broad range of oxygen and hydrogen isotopic compositions were measured by three generations of off-axis integrated cavity output spectroscopy and cavity ring-down spectroscopy instruments. The analysis procedure encompassed small (less than 2ppt for delta super(2)H and 1ppt for delta super(18)O) and large (up to 201ppt for delta super(2)H and 25ppt for delta super(18)O) differences in isotopic compositions between adjacent sample vials. Samples were injected 18 times each, and the between-sample memory effect was quantified for each analysis run. Results showed that samples adversely affected by between-sample isotopic differences stabilised after seven-eight injections. The between-sample memory effect ranged from 14% and 9% for delta super(2)H and delta super(18)O measurements, respectively, but declined to negligible carryover (between 0.1% and 0.3% for both isotopes) when the first ten injections of each sample were discarded. The measurement variability (range and standard deviation) was strongly dependent on the isotopic difference between adjacent vials. Standard deviations were up to 7.5ppt for delta super(2)H and 0.54ppt for delta super(18)O when all injections were retained in the computation of the reportable delta -value, but a significant increase in measurement precision (standard deviation in the range 0.1ppt-1.0ppt for delta super(2)H and 0.05ppt-0.17ppt for delta super(18)O) was obtained when the first eight injections were discarded. In conclusion, this study provided a practical solution to mitigate between-sample memory effects in the isotopic analysis of water samples by laser spectroscopy. |
---|---|
ISSN: | 1027-5606 1607-7938 |