Magnetic stirring-assisted dispersive liquid–liquid microextraction followed by high performance liquid chromatography for determination of phthalate esters in drinking and environmental water samples

A simple, fast and efficient method for the preconcentration of phthalate esters (PEs) in water samples was developed using magnetic stirring-assisted dispersive liquid–liquid microextraction (MSA-DLLME) followed by high performance liquid chromatography coupled with ultraviolet detection (HPLC–UV)....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2012-10, Vol.100, p.447-453
Hauptverfasser: Ranjbari, Elias, Hadjmohammadi, Mohammad Reza
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A simple, fast and efficient method for the preconcentration of phthalate esters (PEs) in water samples was developed using magnetic stirring-assisted dispersive liquid–liquid microextraction (MSA-DLLME) followed by high performance liquid chromatography coupled with ultraviolet detection (HPLC–UV). This novel microextraction method is based on the fast injection of extracting solvent into the aqueous solution, which is being stirred by a magnetic stirrer, to form a cloudy binary component solvent (aqueous solution:extracting solvent) system. The extraction parameters such as type and volume of extracting solvent, pH of sample, salt addition, extraction time and stirring rate were optimized. Under the optimal conditions (extracting solvent: 200μL dodecane; pH of sample: 6.5; extraction time: 5min; stirring rate: 1000rpm), linearity was observed in the range of 2–1000μgL−1 for dimethyl phthalate (DMP) and 1–1000μgL−1 for diethyl phthalate (DEP), benzyl butyl phthalate (BBP) and di-n-butyl phthalate (DBP) with correlation determination values above 0.99 for them. The limits of detection and quantification were ranged from 0.13 to 0.38μgmL−1 and 0.43 to 1.27μgmL−1, respectively. The ranges of intra-day and inter-day precisions (n=5) at 100μgL−1 of PEs were 1.50–2.65% and 2.31–3.35%, respectively. Finally, the MSA-DLLME method was successfully applied for preconcentration of PEs in drinking and environmental water samples. ► MSA-DLLME–HPLC–UV has been applied for rapid determination of phthalates. ► Dodecane is safer than chlorinated solvents and has better chromatographic behavior. ► Using dodecane, elimination of the evaporation step results in excellent precision. ► Phthalates were determined in mineral, tap, well, river and sea water samples.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2012.08.019