Positive end-expiratory pressure oscillation facilitates brain vascular reactivity monitoring

The pressure reactivity index (PRx) identifies optimal cerebral perfusion pressure after traumatic brain injury. We describe a method to improve PRx precision by induced variations in arterial blood pressure (ABP) using positive end-expiratory pressure (PEEP) modulation (iPRx). Neonatal swine (n = 1...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of applied physiology (1985) 2012-11, Vol.113 (9), p.1362-1368
Hauptverfasser: Brady, Ken M, Easley, R Blaine, Kibler, Kathleen, Kaczka, David W, Andropoulos, Dean, Fraser, 3rd, Charles D, Smielewski, Peter, Czosnyka, Marek, Adams, Gerald J, Rhee, Christopher J, Rusin, Craig G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The pressure reactivity index (PRx) identifies optimal cerebral perfusion pressure after traumatic brain injury. We describe a method to improve PRx precision by induced variations in arterial blood pressure (ABP) using positive end-expiratory pressure (PEEP) modulation (iPRx). Neonatal swine (n = 10) were ventilated with static PEEP and then with PEEP oscillated between 5 and 10 cmH(2)O at a frequency of 1/min. PRx was recorded as a moving correlation coefficient between ABP and intracranial pressure (ICP) from spontaneous ABP activity (0.05-0.003 Hz) during static PEEP. iPRx was similarly recorded with PEEP oscillation-induced ABP waves. The lower limit of autoregulation (LLA) was delineated with continuous cortical laser Doppler flux monitoring. PEEP oscillation increased autoregulation-monitoring precision. The ratios of median absolute deviations to range of possible values for the PRx and iPRx were 9.5% (8.3-13.7%) and 6.2% (4.2-8.7%), respectively (P = 0.006; median, interquartile range). The phase-angle difference between ABP and ICP above LLA was 161° (150°-166°) and below LLA, -31° (-42° to 12°, P < 0.0001). iPRx above LLA was -0.42 (-0.67 to -0.29) and below LLA, 0.32 (0.22-0.43, P = 0.0004). A positive iPRx was 97% specific and 91% sensitive for perfusion pressure below LLA. PEEP oscillation caused stable, low-frequency ABP oscillations that reduced noise in the PRx. Safe translation of these findings to clinical settings is expected to yield more accurate and rapid delineation of individualized optimal perfusion-pressure goals for patients.
ISSN:8750-7587
1522-1601
DOI:10.1152/japplphysiol.00853.2012