Effect of cardiac resynchronization therapy on beat-to-beat T-wave amplitude variability

T-wave amplitude variability (TAV) is a promising non-invasive predictor of arrhythmic events in patients with dilated cardiomyopathy. We aimed to evaluate the effect of cardiac resynchronization therapy (CRT) on native TAV, its relation with left ventricular (LV) reverse remodelling and the occurre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Europace (London, England) England), 2012-11, Vol.14 (11), p.1646-1652
Hauptverfasser: Žižek, David, Cvijić, Marta, Tasič, Jerneja, Jan, Matevž, Frljak, Sabina, Zupan, Igor
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:T-wave amplitude variability (TAV) is a promising non-invasive predictor of arrhythmic events in patients with dilated cardiomyopathy. We aimed to evaluate the effect of cardiac resynchronization therapy (CRT) on native TAV, its relation with left ventricular (LV) reverse remodelling and the occurrence of ventricular tachyarrhythmias (VTs). In this prospective study, we included 40 heart failure patients with left bundle branch block in sinus rhythm (25 male; 16 with ischaemic aetiology; aged 62.7 ± 9.5 years; New York Heart Association class II-IV). Echocardiographic parameters and TAV were evaluated at baseline and 6 months after implantation of CRT device combined with an implantable cardioverter-defibrillator. T-wave amplitude variability was determined by a 20-min high-resolution electrocardiogram Holter recording during native conduction. After TAV assessment, patients were monitored for 15.7 ± 5.2 months for the occurrence of VTs. Decrease in median TAV [from 40.45 μV (24.75-56.00) to 28.15 μV (20.93-37.95), P = 0.004] was observed after 6 months of CRT. However, decrease of median TAV was only noticed in patients with LV reverse remodelling [46.9 μV (27.5-70.0) to 25.8 μV (20.2-32.4), P < 0.001] and in patients without VTs [40.5 μV (27.5-55.9) to 24.4 μV (17.1-31.5), P < 0.001]. Native median TAV > 35.4 µV after 6 months of CRT had an 83% sensitivity and 93% specificity for predicting the occurrence of VTs. Decrease of TAV after CRT is associated with LV reverse remodelling and indicates a reduction of the intrinsic arrhythmogenic substrate. Median TAV after CRT had a good predicting value for VT occurrence in long-term follow-up.
ISSN:1099-5129
1532-2092
DOI:10.1093/europace/eus055