Novel Infectious Agent-Free Hemostatic Material (TDM-621) in Cardiovascular Surgery
Subjects: Currently, hemostatic materials made from human blood components and animal-derived collagen is used for controlling operative hemorrhage in the cardiovascular surgery field. In this study, we focused on an entirely synthetic self-assembling peptide (development code: TDM-621) that gels wh...
Gespeichert in:
Veröffentlicht in: | Annals of Thoracic and Cardiovascular Surgery 2012/09/14, Vol.18(5), pp.444-451 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Subjects: Currently, hemostatic materials made from human blood components and animal-derived collagen is used for controlling operative hemorrhage in the cardiovascular surgery field. In this study, we focused on an entirely synthetic self-assembling peptide (development code: TDM-621) that gels when in contact with blood or other bodily fluids and stops bleeding upon contact with a wound site. We investigated its usefulness as a hemostatic material in animal and clinical studies. Methods: Before we began the clinical study, we demonstrated the hemostasis efficacy and safety of TDM-621 in animal experimental models. Twenty-five patients (22 men, 3 women) were enrolled in the clinical study, and the following procedures were performed: 1) coronary artery bypass graft (CABG) (n = 9), 2) abdominal aortic graft replacement (n = 4), and 3) peripheral artery bypass (n = 12). The TDM-621 material was applied to a total of 33 vascular anastomotic graft sites (some patients received material at more than one site). Both hemostatic efficacy and safety were examined. Results: A total of 33 anastomotic graft sites in 25 patients were evaluated, and the averaged primary and secondary efficacy rate was 94.5%. No postoperative bleeding or adverse events (including serious adverse events) with a causal relationship to treatment were observed. Conclusion: This study indicated that TDM-621 is a more effective and reliable hemostat than commonly-used general hemostatic agents and, therefore, will be very useful in several cardiovascular surgery applications. |
---|---|
ISSN: | 1341-1098 2186-1005 |
DOI: | 10.5761/atcs.oa.12.01977 |