A study for the setting method of floating roof tank sloshing damping device

Liquid sloshing of oil storage tanks caused by Tokachi-Oki earthquake in 2003 gave severe damage to oil tanks in Tomakomai area. Up to now, we have verified the effect of sloshing damping device by conducting a shaking experiment of a real scale tank. However, the method of setting up this device an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Structural Engineering A, 2011, Vol.57A, pp.53-62
Hauptverfasser: Komatsu, Ryohei, Ida, Tsuyoshi, Hirano, Hirokazu, Muraji, Shigetoshi
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 62
container_issue
container_start_page 53
container_title Journal of Structural Engineering
container_volume 57A
creator Komatsu, Ryohei
Ida, Tsuyoshi
Hirano, Hirokazu
Muraji, Shigetoshi
description Liquid sloshing of oil storage tanks caused by Tokachi-Oki earthquake in 2003 gave severe damage to oil tanks in Tomakomai area. Up to now, we have verified the effect of sloshing damping device by conducting a shaking experiment of a real scale tank. However, the method of setting up this device and the verification of the influence on the floating roof that this device brings remain as a problem. In order to verify the setting method of sloshing damping device, we conducted a experiment of loading to sloshing damping device in static and dynamic condition and verified the influence that the rigidity of this device gave to a floating roof. Moreover, we proved this device to be an explosion-proof specification by confirming that the use of this device did not generate an excessive temperature rise.
doi_str_mv 10.11532/structcivil.57A.53
format Article
fullrecord <record><control><sourceid>proquest_jstag</sourceid><recordid>TN_cdi_proquest_miscellaneous_1082208647</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1082208647</sourcerecordid><originalsourceid>FETCH-LOGICAL-j1847-e445bafcec317d9da0fe00e1867f3eba08d97d4a9194bb8275e5347b61c811913</originalsourceid><addsrcrecordid>eNpNkFFLwzAUhYMgOOZ-gS959KUzt2mX9HEMdcLAFwXfQprerpltM5N0sH9v3Zz4cg7n8HG5HELugM0Bcp4-hOgHE4092Haei-U851dkAlJCIlP2cUNmIdiSsQJYnop8QjZLGuJQHWntPI0N0oAx2n5LO4yNq6irad06faq8G1PU_ScNrQvNT1Xpbn9yPFiDt-S61m3A2a9PyfvT49tqnWxen19Wy02yA5mJBLMsL3Vt0HAQVVFpViNjCHIhao6lZrIqRJXpAoqsLOX4J-Y8E-UCjAQogE_J_fnu3ruvAUNUnQ0G21b36IaggMk0ZXKRiRFdn9FdiHqLau9tp_1RaR-taVH920uNeyl2Uf6HmEZ7hT3_BjP-bl0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1082208647</pqid></control><display><type>article</type><title>A study for the setting method of floating roof tank sloshing damping device</title><source>J-STAGE Free</source><source>Alma/SFX Local Collection</source><creator>Komatsu, Ryohei ; Ida, Tsuyoshi ; Hirano, Hirokazu ; Muraji, Shigetoshi</creator><creatorcontrib>Komatsu, Ryohei ; Ida, Tsuyoshi ; Hirano, Hirokazu ; Muraji, Shigetoshi</creatorcontrib><description>Liquid sloshing of oil storage tanks caused by Tokachi-Oki earthquake in 2003 gave severe damage to oil tanks in Tomakomai area. Up to now, we have verified the effect of sloshing damping device by conducting a shaking experiment of a real scale tank. However, the method of setting up this device and the verification of the influence on the floating roof that this device brings remain as a problem. In order to verify the setting method of sloshing damping device, we conducted a experiment of loading to sloshing damping device in static and dynamic condition and verified the influence that the rigidity of this device gave to a floating roof. Moreover, we proved this device to be an explosion-proof specification by confirming that the use of this device did not generate an excessive temperature rise.</description><identifier>EISSN: 1881-820X</identifier><identifier>DOI: 10.11532/structcivil.57A.53</identifier><language>jpn</language><publisher>Japan Society of Civil Engineers</publisher><subject>Damping ; damping device ; Devices ; Floating structures ; Loads (forces) ; long-period gr ound motion ; Roofs ; Seismic phenomena ; sloshing ; Storage tanks ; Tanks</subject><ispartof>Journal of Structural Engineering, A, 2011, Vol.57A, pp.53-62</ispartof><rights>2011 by Japan Society of Civil Engineers</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1883,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>Komatsu, Ryohei</creatorcontrib><creatorcontrib>Ida, Tsuyoshi</creatorcontrib><creatorcontrib>Hirano, Hirokazu</creatorcontrib><creatorcontrib>Muraji, Shigetoshi</creatorcontrib><title>A study for the setting method of floating roof tank sloshing damping device</title><title>Journal of Structural Engineering</title><addtitle>Kozo Kogaku Ronbunshu. A</addtitle><description>Liquid sloshing of oil storage tanks caused by Tokachi-Oki earthquake in 2003 gave severe damage to oil tanks in Tomakomai area. Up to now, we have verified the effect of sloshing damping device by conducting a shaking experiment of a real scale tank. However, the method of setting up this device and the verification of the influence on the floating roof that this device brings remain as a problem. In order to verify the setting method of sloshing damping device, we conducted a experiment of loading to sloshing damping device in static and dynamic condition and verified the influence that the rigidity of this device gave to a floating roof. Moreover, we proved this device to be an explosion-proof specification by confirming that the use of this device did not generate an excessive temperature rise.</description><subject>Damping</subject><subject>damping device</subject><subject>Devices</subject><subject>Floating structures</subject><subject>Loads (forces)</subject><subject>long-period gr ound motion</subject><subject>Roofs</subject><subject>Seismic phenomena</subject><subject>sloshing</subject><subject>Storage tanks</subject><subject>Tanks</subject><issn>1881-820X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNpNkFFLwzAUhYMgOOZ-gS959KUzt2mX9HEMdcLAFwXfQprerpltM5N0sH9v3Zz4cg7n8HG5HELugM0Bcp4-hOgHE4092Haei-U851dkAlJCIlP2cUNmIdiSsQJYnop8QjZLGuJQHWntPI0N0oAx2n5LO4yNq6irad06faq8G1PU_ScNrQvNT1Xpbn9yPFiDt-S61m3A2a9PyfvT49tqnWxen19Wy02yA5mJBLMsL3Vt0HAQVVFpViNjCHIhao6lZrIqRJXpAoqsLOX4J-Y8E-UCjAQogE_J_fnu3ruvAUNUnQ0G21b36IaggMk0ZXKRiRFdn9FdiHqLau9tp_1RaR-taVH920uNeyl2Uf6HmEZ7hT3_BjP-bl0</recordid><startdate>2011</startdate><enddate>2011</enddate><creator>Komatsu, Ryohei</creator><creator>Ida, Tsuyoshi</creator><creator>Hirano, Hirokazu</creator><creator>Muraji, Shigetoshi</creator><general>Japan Society of Civil Engineers</general><scope>7SM</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>2011</creationdate><title>A study for the setting method of floating roof tank sloshing damping device</title><author>Komatsu, Ryohei ; Ida, Tsuyoshi ; Hirano, Hirokazu ; Muraji, Shigetoshi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j1847-e445bafcec317d9da0fe00e1867f3eba08d97d4a9194bb8275e5347b61c811913</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>jpn</language><creationdate>2011</creationdate><topic>Damping</topic><topic>damping device</topic><topic>Devices</topic><topic>Floating structures</topic><topic>Loads (forces)</topic><topic>long-period gr ound motion</topic><topic>Roofs</topic><topic>Seismic phenomena</topic><topic>sloshing</topic><topic>Storage tanks</topic><topic>Tanks</topic><toplevel>online_resources</toplevel><creatorcontrib>Komatsu, Ryohei</creatorcontrib><creatorcontrib>Ida, Tsuyoshi</creatorcontrib><creatorcontrib>Hirano, Hirokazu</creatorcontrib><creatorcontrib>Muraji, Shigetoshi</creatorcontrib><collection>Earthquake Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Journal of Structural Engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Komatsu, Ryohei</au><au>Ida, Tsuyoshi</au><au>Hirano, Hirokazu</au><au>Muraji, Shigetoshi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A study for the setting method of floating roof tank sloshing damping device</atitle><jtitle>Journal of Structural Engineering</jtitle><addtitle>Kozo Kogaku Ronbunshu. A</addtitle><date>2011</date><risdate>2011</risdate><volume>57A</volume><spage>53</spage><epage>62</epage><pages>53-62</pages><eissn>1881-820X</eissn><abstract>Liquid sloshing of oil storage tanks caused by Tokachi-Oki earthquake in 2003 gave severe damage to oil tanks in Tomakomai area. Up to now, we have verified the effect of sloshing damping device by conducting a shaking experiment of a real scale tank. However, the method of setting up this device and the verification of the influence on the floating roof that this device brings remain as a problem. In order to verify the setting method of sloshing damping device, we conducted a experiment of loading to sloshing damping device in static and dynamic condition and verified the influence that the rigidity of this device gave to a floating roof. Moreover, we proved this device to be an explosion-proof specification by confirming that the use of this device did not generate an excessive temperature rise.</abstract><pub>Japan Society of Civil Engineers</pub><doi>10.11532/structcivil.57A.53</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 1881-820X
ispartof Journal of Structural Engineering, A, 2011, Vol.57A, pp.53-62
issn 1881-820X
language jpn
recordid cdi_proquest_miscellaneous_1082208647
source J-STAGE Free; Alma/SFX Local Collection
subjects Damping
damping device
Devices
Floating structures
Loads (forces)
long-period gr ound motion
Roofs
Seismic phenomena
sloshing
Storage tanks
Tanks
title A study for the setting method of floating roof tank sloshing damping device
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T14%3A24%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_jstag&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20study%20for%20the%20setting%20method%20of%20floating%20roof%20tank%20sloshing%20damping%20device&rft.jtitle=Journal%20of%20Structural%20Engineering&rft.au=Komatsu,%20Ryohei&rft.date=2011&rft.volume=57A&rft.spage=53&rft.epage=62&rft.pages=53-62&rft.eissn=1881-820X&rft_id=info:doi/10.11532/structcivil.57A.53&rft_dat=%3Cproquest_jstag%3E1082208647%3C/proquest_jstag%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1082208647&rft_id=info:pmid/&rfr_iscdi=true