A study for the setting method of floating roof tank sloshing damping device

Liquid sloshing of oil storage tanks caused by Tokachi-Oki earthquake in 2003 gave severe damage to oil tanks in Tomakomai area. Up to now, we have verified the effect of sloshing damping device by conducting a shaking experiment of a real scale tank. However, the method of setting up this device an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Structural Engineering A, 2011, Vol.57A, pp.53-62
Hauptverfasser: Komatsu, Ryohei, Ida, Tsuyoshi, Hirano, Hirokazu, Muraji, Shigetoshi
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Liquid sloshing of oil storage tanks caused by Tokachi-Oki earthquake in 2003 gave severe damage to oil tanks in Tomakomai area. Up to now, we have verified the effect of sloshing damping device by conducting a shaking experiment of a real scale tank. However, the method of setting up this device and the verification of the influence on the floating roof that this device brings remain as a problem. In order to verify the setting method of sloshing damping device, we conducted a experiment of loading to sloshing damping device in static and dynamic condition and verified the influence that the rigidity of this device gave to a floating roof. Moreover, we proved this device to be an explosion-proof specification by confirming that the use of this device did not generate an excessive temperature rise.
ISSN:1881-820X
DOI:10.11532/structcivil.57A.53