Quantitative susceptibility mapping for investigating subtle susceptibility variations in the human brain

Quantitative susceptibility mapping (QSM) is a novel magnetic resonance-based technique that determines tissue magnetic susceptibility from measurements of the magnetic field perturbation. Due to the ill-posed nature of this problem, regularization strategies are generally required to reduce streaki...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:NeuroImage (Orlando, Fla.) Fla.), 2012-09, Vol.62 (3), p.2083-2100
Hauptverfasser: Schweser, Ferdinand, Sommer, Karsten, Deistung, Andreas, Reichenbach, Jürgen Rainer
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Quantitative susceptibility mapping (QSM) is a novel magnetic resonance-based technique that determines tissue magnetic susceptibility from measurements of the magnetic field perturbation. Due to the ill-posed nature of this problem, regularization strategies are generally required to reduce streaking artifacts on the computed maps. The present study introduces a new algorithm for calculating the susceptibility distribution utilizing a priori information on its regional homogeneity derived from gradient echo phase images and analyzes the impact of erroneous a priori information on susceptibility map fidelity. The algorithm, Homogeneity Enabled Incremental Dipole Inversion (HEIDI), was investigated with a special focus on the reconstruction of subtle susceptibility variations in a numerical model and in volunteer data and was compared with two recently published approaches, Thresholded K-space Division (TKD) and Morphology Enabled Dipole Inversion (MEDI). HEIDI resulted in susceptibility maps without streaking artifacts and excellent depiction of subtle susceptibility variations in most regions. By investigating HEIDI susceptibility maps acquired with the volunteers' heads in different orientations, it was demonstrated that the apparent magnetic susceptibility distribution of human brain tissue considerably depends on the direction of the main magnetic field. [Display omitted] ► Homogeneity information can be used to suppress streaking artifacts in QSM. ► Erroneous a priori information compromises susceptibility reconstruction. ► Depiction of magnetic susceptibility variations depends on the chosen QSM algorithm. ► Magnetic susceptibility depends on orientation with respect to the magnetic field.
ISSN:1053-8119
1095-9572
DOI:10.1016/j.neuroimage.2012.05.067