Novel Sensors for Batch and Flow Injection Analysis of Histamine Based on Crown Ethers
Six types of histamine potentiometric sensors are developed. They are based on using dibenzo‐30‐crown‐10 (DB30C10) with potassium tetrakis(p‐chlorophenyl)borate lipophilic additive (Type I), dibenzo‐30‐crown‐10 without additive (Type II), dibenzo‐24‐crown‐8 (DB24C8) with the same additive (Type III)...
Gespeichert in:
Veröffentlicht in: | Electroanalysis (New York, N.Y.) N.Y.), 2012-05, Vol.24 (5), p.1226-1235 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1235 |
---|---|
container_issue | 5 |
container_start_page | 1226 |
container_title | Electroanalysis (New York, N.Y.) |
container_volume | 24 |
creator | Elmosallamy, Mohamed A. F. |
description | Six types of histamine potentiometric sensors are developed. They are based on using dibenzo‐30‐crown‐10 (DB30C10) with potassium tetrakis(p‐chlorophenyl)borate lipophilic additive (Type I), dibenzo‐30‐crown‐10 without additive (Type II), dibenzo‐24‐crown‐8 (DB24C8) with the same additive (Type III), dibenzo‐24‐crown‐8 without additive (Type IV), dibenzo‐18‐crown‐6 with the additive (Type V) and dibenzo‐18‐crown‐6 without additive (Type VI) as neutral carriers for histamine. Sensors based on dibenzo‐30‐crown‐10 with (PTp‐C1PB) lipophilic additive (Type I) and dibenzo‐30‐crown‐10 without additive (Type II) show good response. The other sensors Types III–VI show poor response in terms of calibration range and slope. |
doi_str_mv | 10.1002/elan.201100674 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1038304686</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1038304686</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4264-e251772116f9b3a9361b85edc2253163a94e2f452c12968b6f2ce3c9110b41f43</originalsourceid><addsrcrecordid>eNqFkMtPwjAcgBejiYhePffoZdjXuvWIhFdCZiI-Ei9NKb-F4VixHSL_vSUzxJunvr7vl_SLoluCewRjeg-VrnsUk3AQKT-LOiShJOYEy_OwxxzHmMn0Mrryfo0xloLLTvSa2y-o0Bxqb51HhXXoQTdmhXS9RKPK7tG0XoNpSlujfq2rgy89sgWalL7Rm7KGgHtYovA8cHZfo2GzAuevo4tCVx5uftdu9DIaPg8m8exxPB30Z7HhVPAYaELSlBIiCrlgWjJBFlkCS0NpwogINxxowRNqCJUiW4iCGmBGhj8uOCk460Z37dyts5878I3alN5AFVKA3XlFMMsY5iITAe21qHHWeweF2rpyo90hQOoYUB0DqlPAIMhW2JcVHP6h1XDWz_-6ceuGTPB9crX7UCJlaaLe8rHCc5mPxu-ZemI_G4SCDw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1038304686</pqid></control><display><type>article</type><title>Novel Sensors for Batch and Flow Injection Analysis of Histamine Based on Crown Ethers</title><source>Wiley Online Library All Journals</source><creator>Elmosallamy, Mohamed A. F.</creator><creatorcontrib>Elmosallamy, Mohamed A. F.</creatorcontrib><description>Six types of histamine potentiometric sensors are developed. They are based on using dibenzo‐30‐crown‐10 (DB30C10) with potassium tetrakis(p‐chlorophenyl)borate lipophilic additive (Type I), dibenzo‐30‐crown‐10 without additive (Type II), dibenzo‐24‐crown‐8 (DB24C8) with the same additive (Type III), dibenzo‐24‐crown‐8 without additive (Type IV), dibenzo‐18‐crown‐6 with the additive (Type V) and dibenzo‐18‐crown‐6 without additive (Type VI) as neutral carriers for histamine. Sensors based on dibenzo‐30‐crown‐10 with (PTp‐C1PB) lipophilic additive (Type I) and dibenzo‐30‐crown‐10 without additive (Type II) show good response. The other sensors Types III–VI show poor response in terms of calibration range and slope.</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.201100674</identifier><language>eng</language><publisher>Weinheim: WILEY-VCH Verlag</publisher><subject>Additives ; Calibration ; Carriers ; Crown ethers ; Determination of histamine ; Flow injection analysis ; Histamines ; Lipophilic additives ; Potassium ; Potentiometry ; Sensors</subject><ispartof>Electroanalysis (New York, N.Y.), 2012-05, Vol.24 (5), p.1226-1235</ispartof><rights>Copyright © 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4264-e251772116f9b3a9361b85edc2253163a94e2f452c12968b6f2ce3c9110b41f43</citedby><cites>FETCH-LOGICAL-c4264-e251772116f9b3a9361b85edc2253163a94e2f452c12968b6f2ce3c9110b41f43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Felan.201100674$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Felan.201100674$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1416,27922,27923,45572,45573</link.rule.ids></links><search><creatorcontrib>Elmosallamy, Mohamed A. F.</creatorcontrib><title>Novel Sensors for Batch and Flow Injection Analysis of Histamine Based on Crown Ethers</title><title>Electroanalysis (New York, N.Y.)</title><addtitle>Electroanalysis</addtitle><description>Six types of histamine potentiometric sensors are developed. They are based on using dibenzo‐30‐crown‐10 (DB30C10) with potassium tetrakis(p‐chlorophenyl)borate lipophilic additive (Type I), dibenzo‐30‐crown‐10 without additive (Type II), dibenzo‐24‐crown‐8 (DB24C8) with the same additive (Type III), dibenzo‐24‐crown‐8 without additive (Type IV), dibenzo‐18‐crown‐6 with the additive (Type V) and dibenzo‐18‐crown‐6 without additive (Type VI) as neutral carriers for histamine. Sensors based on dibenzo‐30‐crown‐10 with (PTp‐C1PB) lipophilic additive (Type I) and dibenzo‐30‐crown‐10 without additive (Type II) show good response. The other sensors Types III–VI show poor response in terms of calibration range and slope.</description><subject>Additives</subject><subject>Calibration</subject><subject>Carriers</subject><subject>Crown ethers</subject><subject>Determination of histamine</subject><subject>Flow injection analysis</subject><subject>Histamines</subject><subject>Lipophilic additives</subject><subject>Potassium</subject><subject>Potentiometry</subject><subject>Sensors</subject><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNqFkMtPwjAcgBejiYhePffoZdjXuvWIhFdCZiI-Ei9NKb-F4VixHSL_vSUzxJunvr7vl_SLoluCewRjeg-VrnsUk3AQKT-LOiShJOYEy_OwxxzHmMn0Mrryfo0xloLLTvSa2y-o0Bxqb51HhXXoQTdmhXS9RKPK7tG0XoNpSlujfq2rgy89sgWalL7Rm7KGgHtYovA8cHZfo2GzAuevo4tCVx5uftdu9DIaPg8m8exxPB30Z7HhVPAYaELSlBIiCrlgWjJBFlkCS0NpwogINxxowRNqCJUiW4iCGmBGhj8uOCk460Z37dyts5878I3alN5AFVKA3XlFMMsY5iITAe21qHHWeweF2rpyo90hQOoYUB0DqlPAIMhW2JcVHP6h1XDWz_-6ceuGTPB9crX7UCJlaaLe8rHCc5mPxu-ZemI_G4SCDw</recordid><startdate>201205</startdate><enddate>201205</enddate><creator>Elmosallamy, Mohamed A. F.</creator><general>WILEY-VCH Verlag</general><general>WILEY‐VCH Verlag</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>201205</creationdate><title>Novel Sensors for Batch and Flow Injection Analysis of Histamine Based on Crown Ethers</title><author>Elmosallamy, Mohamed A. F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4264-e251772116f9b3a9361b85edc2253163a94e2f452c12968b6f2ce3c9110b41f43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Additives</topic><topic>Calibration</topic><topic>Carriers</topic><topic>Crown ethers</topic><topic>Determination of histamine</topic><topic>Flow injection analysis</topic><topic>Histamines</topic><topic>Lipophilic additives</topic><topic>Potassium</topic><topic>Potentiometry</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Elmosallamy, Mohamed A. F.</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Elmosallamy, Mohamed A. F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Novel Sensors for Batch and Flow Injection Analysis of Histamine Based on Crown Ethers</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><addtitle>Electroanalysis</addtitle><date>2012-05</date><risdate>2012</risdate><volume>24</volume><issue>5</issue><spage>1226</spage><epage>1235</epage><pages>1226-1235</pages><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>Six types of histamine potentiometric sensors are developed. They are based on using dibenzo‐30‐crown‐10 (DB30C10) with potassium tetrakis(p‐chlorophenyl)borate lipophilic additive (Type I), dibenzo‐30‐crown‐10 without additive (Type II), dibenzo‐24‐crown‐8 (DB24C8) with the same additive (Type III), dibenzo‐24‐crown‐8 without additive (Type IV), dibenzo‐18‐crown‐6 with the additive (Type V) and dibenzo‐18‐crown‐6 without additive (Type VI) as neutral carriers for histamine. Sensors based on dibenzo‐30‐crown‐10 with (PTp‐C1PB) lipophilic additive (Type I) and dibenzo‐30‐crown‐10 without additive (Type II) show good response. The other sensors Types III–VI show poor response in terms of calibration range and slope.</abstract><cop>Weinheim</cop><pub>WILEY-VCH Verlag</pub><doi>10.1002/elan.201100674</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1040-0397 |
ispartof | Electroanalysis (New York, N.Y.), 2012-05, Vol.24 (5), p.1226-1235 |
issn | 1040-0397 1521-4109 |
language | eng |
recordid | cdi_proquest_miscellaneous_1038304686 |
source | Wiley Online Library All Journals |
subjects | Additives Calibration Carriers Crown ethers Determination of histamine Flow injection analysis Histamines Lipophilic additives Potassium Potentiometry Sensors |
title | Novel Sensors for Batch and Flow Injection Analysis of Histamine Based on Crown Ethers |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T09%3A05%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Novel%20Sensors%20for%20Batch%20and%20Flow%20Injection%20Analysis%20of%20Histamine%20Based%20on%20Crown%20Ethers&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Elmosallamy,%20Mohamed%20A.%20F.&rft.date=2012-05&rft.volume=24&rft.issue=5&rft.spage=1226&rft.epage=1235&rft.pages=1226-1235&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.201100674&rft_dat=%3Cproquest_cross%3E1038304686%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1038304686&rft_id=info:pmid/&rfr_iscdi=true |