STRUCTURAL PERFORMANCE OF PRECAST-CONCRETE JOINTS UTILIZING NON-WELDED SPLICE IN PRECAST-WALL RC STRUCTURES
In the precast-wall RC structures, the cotter-bars installed in the joints have been flare-welded. However, in terms of the assurance of the quality at construction cite, non-welding method is preferable for the connection of cotter-bars. In this research, in order to develop non-welding method, sta...
Gespeichert in:
Veröffentlicht in: | Journal of Structural and Construction Engineering (Transactions of AIJ) 2011/12/30, Vol.76(670), pp.2133-2141 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng ; jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In the precast-wall RC structures, the cotter-bars installed in the joints have been flare-welded. However, in terms of the assurance of the quality at construction cite, non-welding method is preferable for the connection of cotter-bars. In this research, in order to develop non-welding method, static loading tests are carried out for the total of 17 specimens with I-, T-, L-shaped vertical and horizontal joints utilizing clip-type splices as well as flare-welding. Each specimen has practical configuration of shear-cotters. Major findings include: (1) vertical joints utilizing clip-type splices exhibit the ultimate strength similar to those utilizing flare-welding, and (2) T- and L-shaped vertical joints exhibit approximately 0.8 times ultimate strength of I-shaped vertical joints due to the inclination of the angles of concrete compression struts developed in in-plane and out-of-plane walls. |
---|---|
ISSN: | 1340-4202 1881-8153 |
DOI: | 10.3130/aijs.76.2133 |