Comparison of Different Distal Designs of Femoral Components and Their Effects on Bone Remodeling in 1-Stage Bilateral Total Hip Arthroplasty
Abstract To evaluate the effects of distal design of a proximally coated femoral component on periprosthetic bone remodeling, we prospectively performed 21 one-stage bilateral total hip arthroplasties using a distally tapered and a distally cylindrical stem with the same proximal design, randomized...
Gespeichert in:
Veröffentlicht in: | The Journal of arthroplasty 2012-09, Vol.27 (8), p.1538-1543 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract To evaluate the effects of distal design of a proximally coated femoral component on periprosthetic bone remodeling, we prospectively performed 21 one-stage bilateral total hip arthroplasties using a distally tapered and a distally cylindrical stem with the same proximal design, randomized to side. All hips showed good outcomes clinically and radiographically at the final follow-up, average of 7 years postoperatively. Cancellous condensation was always found in Gruen's zones 2 and 6 around the cylindrical stem and in regions between zones 2 and 3 and between zones 6 and 5 around the tapered stem. Bone mineral density of Gruen's zones 2 and 6 was significantly lower around the tapered stem. These results suggested more distal loading in hips with the tapered stem than in those with the cylindrical stem. |
---|---|
ISSN: | 0883-5403 1532-8406 |
DOI: | 10.1016/j.arth.2012.01.031 |