Implantation of a drug-eluting stent with a different drug (switch strategy) in patients with drug-eluting stent restenosis. Results from a prospective multicenter study (RIBS III [Restenosis Intra-Stent: Balloon Angioplasty Versus Drug-Eluting Stent])

This study sought to assess the effectiveness of a strategy of using drug-eluting stents (DES) with a different drug (switch) in patients with DES in-stent restenosis (ISR). Treatment of patients with DES ISR remains a challenge. The RIBS-III (Restenosis Intra-Stent: Balloon Angioplasty Versus Drug-...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JACC. Cardiovascular interventions 2012-07, Vol.5 (7), p.728-737
Hauptverfasser: Alfonso, Fernando, Pérez-Vizcayno, Maria J, Dutary, Jaime, Zueco, Javier, Cequier, Angel, García-Touchard, Arturo, Martí, Vicens, Lozano, Iñigo, Angel, Juan, Hernández, José M, López-Mínguez, José R, Melgares, Rafael, Moreno, Raúl, Seidelberger, Bernhard, Fernández, Cristina, Hernandez, Rosana
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study sought to assess the effectiveness of a strategy of using drug-eluting stents (DES) with a different drug (switch) in patients with DES in-stent restenosis (ISR). Treatment of patients with DES ISR remains a challenge. The RIBS-III (Restenosis Intra-Stent: Balloon Angioplasty Versus Drug-Eluting Stent) study was a prospective, multicenter study that aimed to assess results of coronary interventions in patients with DES ISR. The use of a different DES was the recommended strategy. The main angiographic endpoint was minimal lumen diameter at 9-month follow-up. The main clinical outcome measure was a composite of cardiac death, myocardial infarction, and target lesion revascularization. This study included 363 consecutive patients with DES ISR from 12 Spanish sites. The different-DES strategy was used in 274 patients (75%) and alternative therapeutic modalities (no switch) in 89 patients (25%). Baseline characteristics were similar in the 2 groups, although lesion length was longer in the switch group. At late angiographic follow-up (77% of eligible patients, median: 278 days) minimal lumen diameter was larger (1.86 ± 0.7 mm vs. 1.40 ± 0.8 mm, p = 0.003) and recurrent restenosis rate lower (22% vs. 40%, p = 0.008) in the different-DES group. At the last clinical follow-up (99% of patients, median: 771 days), the combined clinical endpoint occurred less frequently (23% vs. 35%, p = 0.039) in the different-DES group. After adjustment using propensity score analyses, restenosis rate (relative risk: 0.41, 95% confidence interval [CI]: 0.21 to 0.80, p = 0.01), minimal lumen diameter (difference: 0.41 mm, 95% CI: 0.19 to 0.62, p = 0.001), and the event-free survival (hazard ratio: 0.56, 95% CI: 0.33 to 0.96, p = 0.038) remained significantly improved in the switch group. In patients with DES ISR, the implantation of a different DES provides superior late clinical and angiographic results than do alternative interventional modalities.