A 1-Year Prospective Study on Co-Axis® Implants Immediately Loaded with a Full Ceramic Crown

ABSTRACT Introduction: The Co‐Axis® implant (Southern Implants®, Irene, South Africa) has a 12‐degree angle in the implant neck to overcome angulation problems. Aim: To examine bone loss, peri‐implant health, and aesthetical outcome after 1‐year follow‐up. Materials and Methods: Fifteen single impla...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical implant dentistry and related research 2012-05, Vol.14 (s1), p.e126-e138
Hauptverfasser: Vandeweghe, Stefan, Cosyn, Jan, Thevissen, Eric, Van den Berghe, Linda, De Bruyn, Hugo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:ABSTRACT Introduction: The Co‐Axis® implant (Southern Implants®, Irene, South Africa) has a 12‐degree angle in the implant neck to overcome angulation problems. Aim: To examine bone loss, peri‐implant health, and aesthetical outcome after 1‐year follow‐up. Materials and Methods: Fifteen single implants were placed in 14 patients in the premaxilla and immediately loaded with a screw‐retained full ceramic crown. Periapical radiographs and standardized photographs were taken to determine bone loss and soft tissue changes. Plaque and bleeding levels were assessed. Patients' satisfaction was measured using the Oral Health Impact Profile‐14 questionnaire. Results: After 1 year, all implants survived and mean bone loss was 1.20 mm, with no significant changes after 6 months. Plaque levels were low and no significant changes were observed. Bleeding levels decreased during the initial 3 months, but were constant thereafter. Before final torqueing was performed after 6 months, four cases of screw loosening occurred. Also, one crown had a piece of porcelain chipped off. Patients reported an overall increase in well‐being. A mean midfacial recession of 0.37 mm was observed. The mesial papilla showed a slight increase of 0.14 mm, while the distal papilla decreased 0.35 mm. Conclusion: With 100% survival and stable bone levels after 6 months, the Co‐Axis implant showed a good clinical outcome when immediately loaded. The use of a full ceramic crown as a first and final restoration resulted in a good aesthetic outcome with few changes in papilla fill, although midfacial soft tissue was stable only after 1 year.
ISSN:1523-0899
1708-8208