Clinical implication of right ventricular to left ventricular interlead sensed electrical delay in cardiac resynchronization therapy

To evaluate the clinical implication of right ventricular (RV) to left ventricular (LV) interlead sensed electrical delay (RV-LVs) and the relation to ventricular lead position in cardiac resynchronization therapy (CRT). Eighty-five consecutive CRT patients (mean age 66 ± 11 years) received LV lead...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Europace (London, England) England), 2012-07, Vol.14 (7), p.986-993
Hauptverfasser: Kristiansen, Hans Morten, Hovstad, Thomas, Vollan, Gaute, Keilegavlen, Haavard, Faerestrand, Svein
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To evaluate the clinical implication of right ventricular (RV) to left ventricular (LV) interlead sensed electrical delay (RV-LVs) and the relation to ventricular lead position in cardiac resynchronization therapy (CRT). Eighty-five consecutive CRT patients (mean age 66 ± 11 years) received LV lead prospectively targeted to the latest mechanical activated segment (concordant), assessed by two-dimensional speckle tracking radial strain (ST-RS) echocardiography. The RV lead was randomized to RV apex (n= 43) or RV high posterior septum (n= 42). Right ventricular to left ventricular interlead sensed electrical delay was obtained during the CRT implant procedure. Intraventricular dyssynchrony was evaluated by ST-RS echocardiography. Interventricular mechanical delay (IVMD) was measured by using pulse-wave Doppler. Separated by the median RV-LVs (82 ms), a long RV-LVs demonstrated more LV end-systolic volume (LVESV) reduction than a short RV-LVs (-27 ± 20 vs. -16 ± 22%; P= 0.02), 6 months after CRT (6FU). Right ventricular to left ventricular interlead sensed electrical delay correlated to IVMD (r = 0.50; P< 0.001) and intraventricular dyssynchrony (r = 0.25; P= 0.02) at baseline. Concordant LV leads (n= 61) demonstrated superior reduction of LVESV (P= 0.005) 6 months after CRT; however, both RV lead positions had similar effects. Right ventricular to left ventricular interlead sensed electrical delay was irrespective to LV lead concordance and RV lead position (P= ns). Independent predictors to reverse remodelling (reduction of LVESV ≥ 15%) at 6FU were concordant LV lead (odds ratio, 3.210; P= 0.029) and IVMD (odds ratio, 1.028; P= 0.026). Right ventricular to left ventricular interlead sensed electrical delay was not predictive to LV reverse remodelling affected by CRT at 6FU. Concordant LV leads demonstrated superior LV reverse remodelling at 6FU. Right ventricular to left ventricular interlead sensed electrical delay was irrespective of ventricular lead position and might be insufficient to target optimal LV lead position in CRT. http://clinicaltrials.gov. Unique identifier: NCT01035489.
ISSN:1099-5129
1532-2092
DOI:10.1093/europace/eur429