Defined Electrical Stimulation Emphasizing Excitability for the Development and Testing of Engineered Skeletal Muscle

Electrical stimulation is required for the maturation of skeletal muscle and as a way to nondestructively monitor muscle development. However, the wrong stimulation parameters can result in electrochemical damage that impairs muscle development/regeneration. The goal of the current study was to dete...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Tissue engineering. Part C, Methods Methods, 2012-05, Vol.18 (5), p.349-357
Hauptverfasser: Khodabukus, Alastair, Baar, Keith
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Electrical stimulation is required for the maturation of skeletal muscle and as a way to nondestructively monitor muscle development. However, the wrong stimulation parameters can result in electrochemical damage that impairs muscle development/regeneration. The goal of the current study was to determine what aspect of an electrical impulse, specifically the pulse amplitude or pulse width, was detrimental to engineered muscle function and subsequently how engineered muscle responded to continuous electrical stimulation for 24 h. Acute stimulation at a pulse amplitude greater than six-times rheobase resulted in a 2.4-fold increase in the half-relaxation time (32.3±0.49 ms vs. 77.4±4.35 ms; p
ISSN:1937-3384
1937-3392