Modern Proximally Tapered Uncemented Stems Can Be Safely Used in Dorr Type C Femoral Bone

Abstract Cementless femoral fixation has become widely accepted in modern total hip arthroplasty. Treating patients who have a stovepipe-shaped femur (Dorr type C) with cementless implants has traditionally been challenging. We treated 53 consecutive patients (60 hips) who had type C bone with ident...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of arthroplasty 2012-06, Vol.27 (6), p.1014-1018
Hauptverfasser: Dalury, David F., MD, Kelley, Todd C., MD, Adams, Mary Jo, BSN
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Cementless femoral fixation has become widely accepted in modern total hip arthroplasty. Treating patients who have a stovepipe-shaped femur (Dorr type C) with cementless implants has traditionally been challenging. We treated 53 consecutive patients (60 hips) who had type C bone with identical tapered, proximally coated implants and postoperative weight bearing as tolerated. At 6 weeks, all 60 hips had radiographically documented bony integration, and at 1 year, there was no evidence of fracture, subsidence, thigh pain, stress shielding, loose stems, or risk of failure. Of those patients, 40 (43 hips) had midterm follow-up (average, 6 years; range, 4-9 years); the findings were the same. We conclude that modern proximally tapered stems can be used with early weight bearing in patients with type C bone.
ISSN:0883-5403
1532-8406
DOI:10.1016/j.arth.2011.12.019