Nanobiocomposite platform based on polyaniline-iron oxide-carbon nanotubes for bacterial detection
The nanocomposite based on polyaniline (PANI)–iron oxide nanoparticles (nFe3O4) and multi walled carbon-nanotubes (CNT) has been fabricated onto indium tin oxide (ITO) coated glass plate via facile electrochemical synthesis of polyaniline in presence of nFe3O4 (~20nm) and CNT (20–80nm in diameter)....
Gespeichert in:
Veröffentlicht in: | Bioelectrochemistry (Amsterdam, Netherlands) Netherlands), 2012-08, Vol.86, p.30-37 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The nanocomposite based on polyaniline (PANI)–iron oxide nanoparticles (nFe3O4) and multi walled carbon-nanotubes (CNT) has been fabricated onto indium tin oxide (ITO) coated glass plate via facile electrochemical synthesis of polyaniline in presence of nFe3O4 (~20nm) and CNT (20–80nm in diameter). The results of transmission electron microscopic studies show evidence of coating of PANI and nFe3O4 onto the CNT. The PANI-nFe3O4–CNT/ITO nanoelectrode has been characterized by Fourier transform infrared spectroscopy, X-ray diffraction and scanning electron microscopy studies. The biotinylated nucleic acid probe sequence consisting of 20 bases has been immobilized onto PANI–nFe3O4–CNT/ITO nanoelectrode using biotin-avidin coupling. It is shown that the PANI-nFe3O4-CNT platform based biosensor can be used to specifically detect bacteria (N. gonorrhoeae) at minute concentration as low as (1×10−19M) indicating high sensitivity within 45s of hybridization time at 298K by differential pulse voltammetry using methylene blue as electroactive indicator. This bacterial sensor has also been tested with 4 positive and 4 negative PCR amplicons of gonorrhoea affected patient samples. The results of these studies have implications towards the fabrication of a handheld device for Neisseria gonorrhoeae detection that may perhaps result in a decrease in the human immunodeficiency virus infections.
[Display omitted]
► PANI–nFe3O4-CNT nanocomposite prepared onto ITO coated glass plate by facile electrochemical synthesis. ► TEM studies show evidence of PANI-nFe3O4-CNT nanocomposite formation with coating of PANI and nFe3O4 onto the CNT. ► 20 mer bases long biotinylated nucleic acid as a model probe for immobilization. ► Very sensitive and specific to detect pathogenic bacteria such as N. gonorrhoeae at low concentration (1×10−19M) displaying high sensitivity. |
---|---|
ISSN: | 1567-5394 1878-562X |
DOI: | 10.1016/j.bioelechem.2012.01.005 |