Changes in Refraction, Ocular Aberrations, and Corneal Structure After Suspending Rigid Gas-Permeable Contact Lens Wear in Keratoconus

PURPOSE:This study reports on changes in visual acuity, ocular higher-order aberrations, and refraction after suspending rigid gas-permeable lens wear for 1 week in 15 patients with moderate to severe keratoconus. Alterations in the anterior surface, central corneal powers and axes, and central corn...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cornea 2012-05, Vol.31 (5), p.500-508
Hauptverfasser: Jinabhai, Amit, OʼDonnell, Clare, Radhakrishnan, Hema
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:PURPOSE:This study reports on changes in visual acuity, ocular higher-order aberrations, and refraction after suspending rigid gas-permeable lens wear for 1 week in 15 patients with moderate to severe keratoconus. Alterations in the anterior surface, central corneal powers and axes, and central corneal thickness were also explored. METHODS:Scheimpflug photography and Hartmann–Shack aberrometry were performed at 2 visits, 7 days apart, after the patients had removed their habitual contact lenses. Subjective refraction and both high- and low-contrast logarithm of the minimum angle of resolution visual acuities were also recorded at both visits. RESULTS:Reductions in both high-contrast visual acuity (P = 0.001) and low-contrast visual acuity (P = 0.002), along with an increase in third-order root mean square aberrations (P = 0.008), occurred after rigid gas-permeable lens wear was suspended in these patients with keratoconus. However, no significant changes in subjective refraction were found over the 1-week period (P ≥ 0.10). Significant correlations were observed between third-order coma root mean square aberrations and the measured high-contrast (rp ≥ 0.59; P ≤ 0.02) and low-contrast visual acuities (rP ≥ 0.61; P ≤ 0.015). In addition to increases in the anterior surface central corneal powers (P ≤ 0.02), a reduction in central corneal thickness also was found between the 2 visits (P = 0.00016). CONCLUSIONS:Changes in the optical and structural parameters of the keratoconic cornea occur after suspending rigid gas-permeable contact lens wear. This information may be of interest to practitioners concerned with prescribing aberration-controlling soft contact lenses for such patients.
ISSN:0277-3740
1536-4798
DOI:10.1097/ICO.0b013e31820f777b