High accuracy field integral measurement for TJNAF beam energy determination

The determination of the beam energy in the experimental hall A of TJNAF (previously CEBAF) accelerator is done through a very accurate measurement of the field integral of a reference dipole magnet, electrically connected in series with the bending magnets transporting the beam from the accelerator...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on applied superconductivity 2000-03, Vol.10 (1), p.1427-1430
Hauptverfasser: Kircher, F., Fabre, J., Gougnaud, F., Humeau, M., Leboeuf, R., Lussignol, Y., Marroncle, J., Matichard, G., Marchand, D., Sellier, J.C., Vernin, P., Veyssiere, C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The determination of the beam energy in the experimental hall A of TJNAF (previously CEBAF) accelerator is done through a very accurate measurement of the field integral of a reference dipole magnet, electrically connected in series with the bending magnets transporting the beam from the accelerator to the experimental area. A new method is used to determine the field integral; this method is described, as well as the calibrations done in the laboratory. Finally, the goal to reach an accuracy of the field integral on the order of 10/sup -5/ has been reached, as it is shown by comparing the results of the beam energy determination obtained on the accelerator with this method to results obtained by other independant methods.
ISSN:1051-8223
1558-2515