Faraday's Induction Experiment in Nano-Transformers
Faraday's induction experiment in a nanometer scale was performed. Various nano-transformers with the smallest coupling area of approximately 1 mum 2 were fabricated, and the induced open circuit voltages were measured. The output responses showed linear dependences on both the magnitude and th...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on nanotechnology 2008-03, Vol.7 (2), p.120-123 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Faraday's induction experiment in a nanometer scale was performed. Various nano-transformers with the smallest coupling area of approximately 1 mum 2 were fabricated, and the induced open circuit voltages were measured. The output responses showed linear dependences on both the magnitude and the frequency of the input current. This suggested that the nano-transformer behaved as a linear transformer. The extracted mutual inductance value was approximately 30 nH and it was several orders larger than the one expected from 1 mum 2 coupling area. |
---|---|
ISSN: | 1536-125X 1941-0085 |
DOI: | 10.1109/TNANO.2007.909068 |