Admixtures In Spent Plutonium Sources And Gamma-Radiation

The isotopic composition of several spent smoke detectors containing plutonium has been investigated. The article also presents the calculated results of 241Am and 241Pu activities in smoke detectors. The received values vary from (0.934±0.028) MBq to (91.2±4.6) MBq. The eguivalent dose rate of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Science future of Lithuania 2009-07, Vol.1 (4), p.42
Hauptverfasser: Pelanyte, Inga, Motiejunas, Stasys, Gudelis, Arunas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The isotopic composition of several spent smoke detectors containing plutonium has been investigated. The article also presents the calculated results of 241Am and 241Pu activities in smoke detectors. The received values vary from (0.934±0.028) MBq to (91.2±4.6) MBq. The eguivalent dose rate of the established gamma radiation vary from 220 nSv/h to 500 nSv/h. A dose caused by artificial radionuclides in spent smoke detectors was evaluated and compared in the article. It has been found out that due to smoke detectors, an annual dose varies from 0.06 mSv to 0.31 mSv. [PUBLICATION ABSTRACT]
ISSN:2029-2341
2029-2252
DOI:10.3846/165