3D interstitial HDR brachytherapy combined with 3D external beam radiotherapy and androgen deprivation for prostate cancer: Preliminary results

Evaluation of feasibility, tolerance and efficiency for a new 3D interstitial HDR brachytherapy technique combined with 3D external beam radiotherapy and androgen deprivation for prostate cancer. Between January 1997 and August 1998 we treated 35 patients with stage cT1-3 N0 M0 prostate cancer. Thir...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Strahlentherapie und Onkologie 2000-08, Vol.176 (8), p.361-367
Hauptverfasser: MARTIN, T, KOCH, S. H, KURCK, R, TUNN, U, ZAMBOGLOU, N, STRASSMANN, G, KOLOTAS, C, BALTAS, D, ROGGE, B, RÖDDIGER, S, VOGT, H.-G, HEYD, R, DANNENBERG, T
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Evaluation of feasibility, tolerance and efficiency for a new 3D interstitial HDR brachytherapy technique combined with 3D external beam radiotherapy and androgen deprivation for prostate cancer. Between January 1997 and August 1998 we treated 35 patients with stage cT1-3 N0 M0 prostate cancer. Thirty-two patients with a follow-up of 12 to 28 months (median: 18 months) were evaluated. After ultrasound-guided transrectal implantation of 4 non-parallel needles, CT based 3D brachytherapy treatment planning ("Offenbach system") was performed. All patients received 4 fractions brachytherapy using a fractional dose of 5 or 7 Gy. Time between each fraction was 14 days. After brachytherapy 3D external irradiation followed up to 39.6 or 45.0 Gy. All patients received androgen deprivation, starting 2 to 19 months before brachytherapy, ending 3 months after 3D external radiotherapy. Posttreatment PSA levels dropped to < 1.5 ng/ml in 29/32 patients (91%). In 25 patients PSA levels were < 0.5 ng/ml, in 4 patients 0.5 to 1.5 ng/ml. In 2 patients we noted biochemical relapse. Transrectal implantation was very well tolerated. Grade 3 acute urinary toxicity occurred in 1 patient. We noted no Grade 2 or higher acute gastrointestinal toxicity. One patient developed a Grade 3 late urinary toxicity. No patient showed late gastrointestinal side effects. All 140 dose-volume histograms for 3D HDR brachytherapy were analyzed. The new 3D HDR brachytherapy technique, combined with 3D external irradiation and androgen deprivation, is a feasible, so far well-tolerated and effective treatment in the short-time follow-up of median 18 months.
ISSN:0179-7158
1439-099X
DOI:10.1007/PL00002344