A new approach to the diagnosis of solid insulation systems based on PD signal inference

The authors have developed digital instrumentation that can measure the amplitude, shape, phase, and number of pulses per cycle. Examples are given of results obtained from an induction motor, a hydrogenerator, a polymeric cable system with a defective joint, and a high-voltage current transformer.

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE electrical insulation magazine 2003-03, Vol.19 (2), p.23-30
Hauptverfasser: Cavallini, A., Montanari, G.C., Contin, A., Pulletti, F.
Format: Magazinearticle
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The authors have developed digital instrumentation that can measure the amplitude, shape, phase, and number of pulses per cycle. Examples are given of results obtained from an induction motor, a hydrogenerator, a polymeric cable system with a defective joint, and a high-voltage current transformer.
ISSN:0883-7554
1558-4402
DOI:10.1109/MEI.2003.1192033