Astrakhan-Mangyshlak Water Conduit: the Corrosion State of the Inner Surface, and Methods for Its Corrosion Protection. Part II. Corrosion Resistance of Metal

Based on the results of inspection, electrochemical experiments, and corrosion tests, the multiple changes in the mechanism of the inner corrosion of pipes along the service long-distance water main cannot be explained by changes in the chemical composition and oxygen content of the water. It is sho...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Protection of metals 2003-01, Vol.39 (1), p.1-5
Hauptverfasser: Reformatskaya, I I, Ashcheulova, I I, Ivleva, G A, Taubaldiev, T S, Murinov, S K, Kostin, D V, Sin'ko, V F, Tastanov, K Kh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Based on the results of inspection, electrochemical experiments, and corrosion tests, the multiple changes in the mechanism of the inner corrosion of pipes along the service long-distance water main cannot be explained by changes in the chemical composition and oxygen content of the water. It is shown that in equally aerated solutions determining the corrosion rate by weighting results in an error of 350-400%. The method developed enables one to ascertain the type and rate of corrosion accurate to 20%.[PUBLICATION ABSTRACT]