Radiation of x-rays using polarized LiNbO3 single crystal in low-pressure ambient gas

The dependence of X-ray intensity on the pressure and type of ambient gas was investigated for LiNbO 3 single crystals polarized in the c-axis direction at pressures of approximately 1 to 30 Pa. Ionization of surrounding gas molecules by the electric field generated by the crystal led to the product...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control ferroelectrics, and frequency control, 2009-09, Vol.56 (9), p.1850-1855
Hauptverfasser: Fukao, S., Nakanishi, Y., Mizoguchi, T., Ito, Y., Yoshikado, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The dependence of X-ray intensity on the pressure and type of ambient gas was investigated for LiNbO 3 single crystals polarized in the c-axis direction at pressures of approximately 1 to 30 Pa. Ionization of surrounding gas molecules by the electric field generated by the crystal led to the production of both positive ions and free electrons. The electrons were accelerated toward a Cu target, radiating both white X-rays and X-rays specific to the crystal or target material by bremsstrahlung. The integrated X-ray intensity per cycle in the energy range 1 to 20 keV showed a local maximum value at a pressure P max . The logarithm of P max was proportional to the Boltzmann factor using the first ionization energy of each ambient gas molecule. The value of P max was found to be independent of the electrical surface area of the crystal. The integrated X-ray intensity was approximated qualitatively by a quadratic function with pressure, which was upwardly convex. It was found that one of the causes of the reduction in X-ray intensity at pressures P > P max is the adsorption of positive ions generated by the ionization of gas molecules on the negative electric surface. It was also discovered that the lifetime of the X-ray radiation device could be improved when the X-ray radiation case was covered with another hermetically sealed decompression case. The gas with the smallest first ionization energy, with a partial pressure of P max , was enclosed inside the X-ray radiation case (inner case) and the gas with the largest first ionization energy was enclosed at a suitable pressure between the inner and outer cases.
ISSN:0885-3010
1525-8955
DOI:10.1109/TUFFC.2009.1260