Reproducibility of the exponential rise technique of CO2 rebreathing for measuring PvCO2 and CvCO2 to non-invasively estimate cardiac output during incremental, maximal treadmill exercise

The purpose of this study was to determine the reproducibility of the indirect Fick method for the measurement of mixed venous carbon dioxide partial pressure (P^sub v^CO^sub 2^) and venous carbon dioxide content (C^sub v^CO^sub 2^) for estimation of cardiac output (Q^sub c^), using the exponential...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of applied physiology 2004-05, Vol.91 (5-6), p.669
Hauptverfasser: Cade, W Todd, Nabar, Sharmila R, Keyser, Randall E
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The purpose of this study was to determine the reproducibility of the indirect Fick method for the measurement of mixed venous carbon dioxide partial pressure (P^sub v^CO^sub 2^) and venous carbon dioxide content (C^sub v^CO^sub 2^) for estimation of cardiac output (Q^sub c^), using the exponential rise method of carbon dioxide rebreathing, during non-steady-state treadmill exercise. Ten healthy participants (eight female and two male) performed three incremental, maximal exercise treadmill tests to exhaustion within 1 week. Non-invasive Q^sub c^ measurements were evaluated at rest, during each 3-min stage, and at peak exercise, across three identical treadmill tests, using the exponential rise technique for measuring mixed venous PCO^sub 2^ and CCO^sub 2^ and estimating venous-arterio carbon dioxide content difference (C^sub v-a^CO^sub 2^). Measurements were divided into measured or estimated variables [heart rate (HR), oxygen consumption (VO^sub 2^), volume of expired carbon dioxide (VCO^sub 2^), end-tidal carbon dioxide (P^sub ET^CO^sub 2^), arterial carbon dioxide partial pressure (P^sub a^CO^sub 2^), venous carbon dioxide partial pressure (P^sub v^CO^sub 2^), and C^sub v-a^CO^sub 2^] and cardiorespiratory variables derived from the measured variables [Q^sub c^, stroke volume (V^sub s^), and arteriovenous oxygen difference (C^sub a-v^O^sub 2^)]. In general, the derived cardiorespiratory variables demonstrated acceptable (R=0.61) to high (R>0.80) reproducibility, especially at higher intensities and peak exercise. Measured variables, excluding P^sub a^CO^sub 2^ and C^sub v-a^CO^sub 2^, also demonstrated acceptable (R=0.6 to 0.79) to high reliability. The current study demonstrated acceptable to high reproducibility of the exponential rise indirect Fick method in measurement of mixed venous PCO^sub 2^ and CCO^sub 2^ for estimation of Q^sub c^ during incremental treadmill exercise testing, especially at high-intensity and peak exercise.[PUBLICATION ABSTRACT]
ISSN:1439-6319
1439-6327
DOI:10.1007/s00421-003-1017-x