Dose uniformity evaluations for gamma radiation processing facility using Monte Carlo simulations and its validation

The gamma radiation processing facilities (GRAPFs) qualify to obtain the license of operation on the basis of the radiological safety of the facility and the accurate radiation dosimetry in the product. The theoretical dose evaluations in the product are carried out using Monte Carlo simulations in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation protection and environment 2024-07, Vol.47 (3), p.164-168
Hauptverfasser: Rajput, Raksha, Garg, Jyoti, George, Jain Reji, Khedkar, Kalpana, Jothish, P. K., Jayachandran, N., Mukherjee, Pradip
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The gamma radiation processing facilities (GRAPFs) qualify to obtain the license of operation on the basis of the radiological safety of the facility and the accurate radiation dosimetry in the product. The theoretical dose evaluations in the product are carried out using Monte Carlo simulations in this work. This is required for optimizing the source loading configuration with the best combination of averaged dose rate and dose uniformity ratio (DUR) to maximize the efficiency of the facility. Three different GRAPFs are chosen for the study. The theoretical results of DUR are validated against the commissioning dosimetry with a variation of
ISSN:0972-0464