DEVELOPMENT OF METAL SLEEVE CONNECTIONS FILLED WITH HIGH STRENGTH GROUT MORTAR FOR CLT STRUCTURES
Main problems with CLT structures are follows; It is necessary to ensure construction accuracy of the joining metal fitting under the bottom of CLT walls to anchor bolts embedded into R/C foundations. The rotational stiffness and bearing capacity of CLT walls are reduced because the compression side...
Gespeichert in:
Veröffentlicht in: | AIJ Journal of Technology and Design 2024/06/20, Vol.30(75), pp.668-673 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Main problems with CLT structures are follows; It is necessary to ensure construction accuracy of the joining metal fitting under the bottom of CLT walls to anchor bolts embedded into R/C foundations. The rotational stiffness and bearing capacity of CLT walls are reduced because the compression side of the CLT shear walls sink into CLT floors when CLT walls are installed on top of CLT floors. The energy absorption capacity decreases due to the slip phenomenon during cyclic loadings. In this report, the metal sleeve connecter filled with high strength grout mortar is developed to solve those problems. |
---|---|
ISSN: | 1341-9463 1881-8188 |
DOI: | 10.3130/aijt.30.668 |