Residual Stress in the Carrier Tape AISI 310S at the Stage of Deposition of the YSZ Buffer Layer when Manufacturing of HTS-2G Wire

Using neutron diffraction we determined internal residual stress in the stainless steel AISI 310S carrier tape with a thickness of 100 µm and a width of 4 mm after mechanical polishing and the ABAD deposition of the textured YSZ buffer layer. It is shown that mechanical polishing causes a slight dis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Technical physics 2024-01, Vol.69 (4), p.883-889
Hauptverfasser: Irodova, A. V., Karpov, I. D., Kruglov, V. S., Krylov, V. E., Shavkin, S. V., Em, V. T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Using neutron diffraction we determined internal residual stress in the stainless steel AISI 310S carrier tape with a thickness of 100 µm and a width of 4 mm after mechanical polishing and the ABAD deposition of the textured YSZ buffer layer. It is shown that mechanical polishing causes a slight distension of the tape in the rolling plane. After the deposition of the YSZ layer, uniform tensile stress of 70 MPa isotropic in the rolling plane was observed inside the tape. Calculations have shown that it results from relaxation of compressive stress acting on the surface of the tape in a layer several times thicker than the YSZ layer. It is assumed that the surface of the tape is plastically deformed during the YSZ deposition.
ISSN:1063-7842
1090-6525
DOI:10.1134/S1063784224030149