Application of Hydrosol to Aerosol Based Metrology to Predict Wafer Defects from Process Chemical Contamination

A method for continuous measurement of particle and particle precursor material in high purity liquids using aerosolization and condensation particle courting (A+CPC) is presented. A process for correlating wafter defects with the concentration values measured using A+CPC using Sequential Spin Coati...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Solid state phenomena 2023-08, Vol.346, p.157-163
Hauptverfasser: Altun, Ali, Oberreit, Derek, Van Schooneveld, Gary, Mizusugi, Hans, Walker, Michael
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A method for continuous measurement of particle and particle precursor material in high purity liquids using aerosolization and condensation particle courting (A+CPC) is presented. A process for correlating wafter defects with the concentration values measured using A+CPC using Sequential Spin Coating + Surface Enhanced Particle Sizing (SSC + SEPS) is described. The method was applied to monitor the rinsate of an ion exchange resin following the SEMI C93 guide. The results showed correlation between the methods and the concentration values were used to calculate a deposition factor (liquid concentration/surface concentration) on the order of 1E5 (#/ml)/(#/cm2).
ISSN:1012-0394
1662-9779
1662-9779
DOI:10.4028/p-CiXeA0