We evaluated the true incidence of seroma formation after laparoscopic repair of incisional hernia with polytetrafluoroethylene (PTFE) patch. In a prospective study, 20 patients who underwent laparoscopic repair of incisional hernia with PTFE were evaluated clinically and with ultrasound examination...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Hernia : the journal of hernias and abdominal wall surgery 2001-09, Vol.5 (3), p.139-141
Hauptverfasser: SUSMALLIAN, S, GEWURTZ, G, EZRI, T, CHARUZI, I
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We evaluated the true incidence of seroma formation after laparoscopic repair of incisional hernia with polytetrafluoroethylene (PTFE) patch. In a prospective study, 20 patients who underwent laparoscopic repair of incisional hernia with PTFE were evaluated clinically and with ultrasound examination for seroma formation up to the 90th postoperative day. Seroma was diagnosed clinically in only 35% of cases, while ultrasound examination revealed the presence of seroma in 100% of patients. Ultrasound examination is a reliable tool for diagnosis of early or delayed postoperative seroma formation following laparoscopic repair of incisional hernia with Gore-Tex Dualmesh.