Statistical Signal Detection Algorithm in Safety Data: A Proprietary Method Compared to Industry Standard Methods
Introduction Several quantitative methods have been established, in pharmacovigilance, to detect signals of disproportionate reporting (SDRs) from databases containing reports of adverse drug reactions (ADRs). The signal detection algorithms (SDAs) and the source of the reporting per product vary, b...
Gespeichert in:
Veröffentlicht in: | Pharmaceutical medicine 2024-07, Vol.38 (4), p.321-329 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction
Several quantitative methods have been established, in pharmacovigilance, to detect signals of disproportionate reporting (SDRs) from databases containing reports of adverse drug reactions (ADRs). The signal detection algorithms (SDAs) and the source of the reporting per product vary, but it is unclear whether any algorithm can provide satisfactory performance using data with such large variance factors.
Objective
Determine the appropriate SDA for Biogen’s internal Global Safety Database (GSD) given the characteristics of the database including frequencies of events, data skewness, outliers, and missing information. Compare performance of standard approaches (EBGM, EB05, PRR, and ROR), well accepted by industry, to a Biogen-developed Machine Learning (ML) Regression Decision Tree (RDT) model, across several Biogen products, to determine a champion SDA.
Methods
All data associated with seven marketed Biogen products were chosen and a historical subset of reported ADRs were considered. Six SDAs (five common industry disproportionality methods) and RDT were evaluated. The SDRs were calculated on training and test data composed of quarterly reporting intervals from 2004–2019. The performance measures used were sensitivity, precision, time to detect new events, and frequency of detected cases for each algorithm for each product. Outcomes in the test data are known a priori and easily compared to predicted outcomes. Validation was performed via rates of misclassification. This work solely represents Biogen’s internal information, intentionally chosen to serve the performance review of its signal detection systems, and results will not necessarily be generalizable to other external sources.
Results
Several algorithms performed differently among products, but no one method dominated any other. Performance was dependent on the thresholds used to define a signal according to different criteria. However, those different statistics subtly influenced the achievable performance. The relative performance of RDT and Medicines and Healthcare products Regulatory Agency (MHRA) algorithms were superior and paired across products. A reduction in precision for all methods spanning the products was present. Hence, companies evaluating signal detection approaches, search for innovative methods to minimize this effect.
Conclusions
In designing signal detection systems, careful consideration should be given to the criteria that are used to define SDRs. The choice of di |
---|---|
ISSN: | 1178-2595 1179-1993 |
DOI: | 10.1007/s40290-024-00530-1 |