Experimental concept validation of a proton therapy range verification system using scattered proton measurements
In recent years, the application of positron emission tomography (PET) for the dose range verification of proton therapy has been proposed. However, the positron distribution is determined by the nuclear reaction cross section; hence, PET may not accurately reflect the dose range primarily influence...
Gespeichert in:
Veröffentlicht in: | Applied physics letters 2024-05, Vol.124 (21) |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In recent years, the application of positron emission tomography (PET) for the dose range verification of proton therapy has been proposed. However, the positron distribution is determined by the nuclear reaction cross section; hence, PET may not accurately reflect the dose range primarily influenced by ionization. Consequently, a proton dose range verification system based on scattered proton measurements has been suggested owing to the similarity in the reaction cross section between Rutherford scattering and ionization. While previous investigations have only verified the feasibility of dose range estimation through simple simulations, the objective of this study is to demonstrate this feasibility through experimental investigation. In this paper, we established an experimental framework for capturing scattered protons and introduced an algorithm that compares measured signal patterns with a reference database to estimate the dose range. A therapeutic beam was irradiated onto the abdominal region of a human phantom, and scattered protons were measured using scintillation detectors placed on the phantom surface. Consequently, the dose range was estimated with error margins of 4.22 ± 3.68 and 0.60 ± 1.03 mm along the beam axis and perpendicular directions to the Bragg peak, respectively. While providing the same level of Bragg peak positioning accuracy as conventional methods, our system features small size, cost-effectiveness, and system simplicity. One notable limitation of our method is the challenge in achieving precise detector positioning, which is crucial for accurate dose range estimation. Future research will focus on improving detector-position accuracy and exploring advanced algorithms for signal analysis to further refine dose range estimations. |
---|---|
ISSN: | 0003-6951 1077-3118 |
DOI: | 10.1063/5.0200467 |