Instability Mitigation of Constant Power Load in Microgrid

This paper proposes a novel stabilizing control method aimed at overcoming the instability challenges posed by the negative incremental resistance characteristics of a constant power load (CPL) within an autonomous microgrid (MG). The proposed stabilization technique integrates a power derivative-in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Arabian journal for science and engineering (2011) 2024-05, Vol.49 (5), p.7341-7358
Hauptverfasser: Hassan, Mohamed A., Worku, Muhammed Y., Eladl, Abdelfattah A., Elkadeem, Mohamed R., Hossain, Md Ismail, Abido, Mohammad A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper proposes a novel stabilizing control method aimed at overcoming the instability challenges posed by the negative incremental resistance characteristics of a constant power load (CPL) within an autonomous microgrid (MG). The proposed stabilization technique integrates a power derivative-integral term with conventional droop control, strategically applied to enhance the MG's dynamic stability in the presence of CPL. The considered MG model, encompassing three inverter-based distributed generations (DGs), a constant impedance load (CIL), and CPL, is meticulously developed and simulated using MATLAB environment. Phase Locked Loop (PLL) is employed to synchronize the CPL with MG. The proposed controller is a key highlight, featuring optimally designed and tuned controller parameters for all DGs, CPL, and PLL. Particle Swarm Optimization (PSO) and Genetic Algorithm (GA) are employed to address the challenges linked to the laborious tuning process of controllers. The simulation results, which include scenarios involving three-phase faults and step changes, provide compelling evidence of the proposed controller's superior performance compared to conventional droop scheme. Furthermore, a comparative analysis is conducted to affirm and quantify the enhancements achieved through the proposed modified droop PSO-based MG controller concerning transient response. The results obtained emphasize the effectiveness of the proposed approach in simultaneously minimizing both overshoot and settling time. In comparison with the conventional controller, the proposed controller demonstrates a substantial decrease in percentage overshoot for the active power of DG3 and DC voltage of the CPL, with values of 93.89 and 99.9%, respectively. The corresponding improvements in settling time are notable, showcasing reductions of 83.11% for the active power of DG3 and 66.1% for the DC voltage of the CPL. When compared to the GA-based controller, the proposed controller exhibits significant percentage overshoot reductions for and DC voltage of the CPL, achieving 79.42 and 99.8%, respectively. Additionally, the settling time records noteworthy improvements, with reductions of 76.19% for the active power of DG3 and 57.57% for the DC voltage of the CPL. To further validate the real-world applicability and effectiveness of the proposed method, a real-time digital simulator (RTDS) is employed. The RTDS experiments results confirm the proposed scheme's ability to enhance MG stability,
ISSN:2193-567X
1319-8025
2191-4281
DOI:10.1007/s13369-024-08813-0