Monte Carlo Simulation of Liver Dosimetry with Yttrium-90 Radionuclide Using Gate: 3D Phantom

This study is aimed to validate 90 Y dosimetry with MC simulation by comparing the TLD measurements results obtained in 3D liqid phantom (LP) and its monte carlo (MC) simulation. In the first step, tumor imitation was filled with 1900 µCi (70.3 MBq) amount of 99m Tc activity in LP. In addition, 24 t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Bulletin of the Lebedev Physics Institute 2024, Vol.51 (1), p.30-37
Hauptverfasser: Karadeniz-Yildirim, Ayşe, Ozkorucuklu, Suat, Tanyildizi-Kokkulunk, Handan, Demir, Mustafa, Yasar, Dogan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study is aimed to validate 90 Y dosimetry with MC simulation by comparing the TLD measurements results obtained in 3D liqid phantom (LP) and its monte carlo (MC) simulation. In the first step, tumor imitation was filled with 1900 µCi (70.3 MBq) amount of 99m Tc activity in LP. In addition, 24 thermoluminescence dosimetry chips (TLD-100) were placed in 8 different locations in the LP. The same measurement system was created in GEANT4 Tomography Emission Application (GATE version 8.1). DoseActor library was defined for 24 points instead of TLDs and doses were taken. In the second step, 90 Y with the amount of 2 mCi (74 MBq) activity and 27 DoseActor libraries were placed in tumor mimic and different locations in LP to calculate the dose distribution with GATE. GATE and TLD results for 99m Tc were compared for validation. The strong correlation coefficient was calculated between the instant absorbed dose rates obtained via TLD measurements and GATE calculations as R 2 = 0.994. At the 90 Y dosimetry, the highest, lowest and mean cumulative absorbed doses calculated by GATE for a half-life were found to be 1.166 × 10 2 ± 3.907 × 10 –1 , 5.440 × 10 1 ± 2.597 × 10 –1 , and 75.145 ± 0.303 Gy in the tumor imitation, and 1.167 × 10 1 ± 1.777 × 10 −1 , 9.929 × 10 −5 ± 6.905 × 10 −5 , 1.169 ± 0.019 Gy in the liver parenchymal tissue imitation, respectively. GATE program is considered to be a promising application in internal radionuclide dosimetry, based on linear correlation between TLD and GATE measurements in our study.
ISSN:1068-3356
1934-838X
DOI:10.3103/S1068335623600201