Vapour pressure measurements on Nd–Te system

Equilibrium vapour pressure measurements were carried out over the neodymium–tellurium samples using the non-isothermal isopiestic method. The samples were equilibrated in the temperature range from 821 to 1100 K. Using vapour pressure data obtained for the composition range ~ 64.0–74.5 at% Te, the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Monatshefte für Chemie 2024-02, Vol.155 (2), p.165-172
Hauptverfasser: Kumar, S. Shyam, Panda, Arun Kumar, Mythili, R., Ganesan, Rajesh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Equilibrium vapour pressure measurements were carried out over the neodymium–tellurium samples using the non-isothermal isopiestic method. The samples were equilibrated in the temperature range from 821 to 1100 K. Using vapour pressure data obtained for the composition range ~ 64.0–74.5 at% Te, the thermodynamic activities of Te were determined. Non-stoichiometry in the NdTe 2 phase has been precisely determined under experimental conditions reported. Graphical abstract
ISSN:0026-9247
1434-4475
DOI:10.1007/s00706-023-03153-5