Rerepair for recurrent mitral regurgitation due to Physio ring dehiscence

A 57-year-old man suffered recurrent mitral regurgitation after dehiscence of a 28 mm Physio ring 3 months after initial repair. We substituted a 30 mm Physio ring in reoperation, enabling successful mitral rerepair. This case points up the need for special care to be taken in determining the size o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:General thoracic and cardiovascular surgery 2003-02, Vol.51 (2), p.71-72
Hauptverfasser: Saito, Akira, Katahira, Seiichiro, Hirata, Kazuhiko, Kitamura, Masaya
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A 57-year-old man suffered recurrent mitral regurgitation after dehiscence of a 28 mm Physio ring 3 months after initial repair. We substituted a 30 mm Physio ring in reoperation, enabling successful mitral rerepair. This case points up the need for special care to be taken in determining the size of rigid rings and suture placement deep enough in annular tissue.
ISSN:1344-4964
1863-6705
1863-6713
DOI:10.1007/BF02719172