Late aortic dissection in a patient with a left ventricular assist device
The limited availability of donor hearts means that an increasing number of transplantation candidates are temporarily or permanently supported by mechanical circulatory assist devices. We report a patient undergoing implantation of a Novacor left ventricular assist device who suffered fatal aortic...
Gespeichert in:
Veröffentlicht in: | General thoracic and cardiovascular surgery 2001-06, Vol.49 (6), p.395-397 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The limited availability of donor hearts means that an increasing number of transplantation candidates are temporarily or permanently supported by mechanical circulatory assist devices. We report a patient undergoing implantation of a Novacor left ventricular assist device who suffered fatal aortic dissection on postoperative day 11 after satisfactory recovery from multiple organ failure. The dissection of the aorta initially presented as an embolic peripheral ischemia. Early complete echocardiography is thus warranted to rule out dissection. |
---|---|
ISSN: | 1344-4964 1863-6705 1863-2092 1863-6713 |
DOI: | 10.1007/BF02913159 |