Study of a new one-way timing method
This paper combines the advantages of both common-view time transfer and one-way timing and proposes a new one-way timing method.Owing to the limitations in users capacity and real-time,common-view time transfer can not provide time service simultaneously for mass users.A zero baseline experiment is...
Gespeichert in:
Veröffentlicht in: | Science China. Physics, mechanics & astronomy mechanics & astronomy, 2012-12, Vol.55 (12), p.2476-2481 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper combines the advantages of both common-view time transfer and one-way timing and proposes a new one-way timing method.Owing to the limitations in users capacity and real-time,common-view time transfer can not provide time service simultaneously for mass users.A zero baseline experiment is carried out to validate its feasibility.Experimental results indicate this new method can achieve a timing accuracy within 5 ns.Users with requirements of rigorous time can employ this method to keep time synchronized with timing labs. |
---|---|
ISSN: | 1674-7348 1869-1927 |
DOI: | 10.1007/s11433-012-4875-6 |