Use of Implants Constructed Using Three-dimensional Titanium Nickelide Mesh to Fill Cavity Defects in the Femur
Acute spherical cavity defects in the distal metaphysis of the femur were created and filled with a mesh implant made of titanium nickelide wire in 15 mature adult male Wistar rats. Analogous defects were created in animals of the control group (n = 15) but were not filled. Filling of the defect in...
Gespeichert in:
Veröffentlicht in: | Biomedical engineering 2017-11, Vol.51 (4), p.267-270 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Acute spherical cavity defects in the distal metaphysis of the femur were created and filled with a mesh implant made of titanium nickelide wire in 15 mature adult male Wistar rats. Analogous defects were created in animals of the control group (n = 15) but were not filled. Filling of the defect in rats of the experimental group was noted 90 days after implantation, but did not occur in rats of the control group. No differences were seen in the clinical picture or pathomorphological or biochemical investigation results between animals of the experimental groups. |
---|---|