Demand response strategy study of a radiant roof cooling system based on the thermal inertia of the building envelope

There is an imbalance between supply and demand in the power system. Implementing demand response control strategies for air-conditioning systems is beneficial to optimize the allocation of power resources. Here, we use two single strategies and a combination strategy for the radiant roof cooling sy...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Building services engineering research & technology 2024-01, Vol.45 (1), p.39-51
Hauptverfasser: Guo, Yidan, Xia, Xueying, Wang, Zhaotai, Liu, Yuhan, Li, Zhen
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:There is an imbalance between supply and demand in the power system. Implementing demand response control strategies for air-conditioning systems is beneficial to optimize the allocation of power resources. Here, we use two single strategies and a combination strategy for the radiant roof cooling system: passive energy storage, global temperature reset, and the passive energy storage-global temperature reset combination strategy to implement demand response control, all of which achieve peak load reduction or shifting by changing the indoor controlled parameters. Based on the thermal inertia of the building envelope, we utilize a TRNSYS model to analyze the performance of three demand response strategies of radiant roof cooling systems in terms of thermal comfort, energy consumption, operating costs, and peak load shifting rates. The findings reveal that implementing demand response strategies can reduce the operating energy consumption of radiant roof cooling systems and facilitate peak load shifting. Among them, the combined response strategy shows the best peak load transfer effect, with a transfer rate of 19.84% and a better operating economy. Meanwhile, we find that the outdoor temperature affects the implementation of demand response strategies for the radiant roof cooling system based on the thermal inertia of the building envelope. Practical application The study has significant application value in the following aspects: Implementing a demand response strategy for the radiant roof cooling system, based on the thermal inertia of the building envelope, can reduce operational energy consumption and achieve peak load shifting. This approach effectively addresses the issue of supply-demand imbalance in the power system. The application of the work could facilitate improved operational energy efficiency, contributing to emissions reduction goals and optimizing the use of intermittent renewable energy systems in power grids.
ISSN:0143-6244
1477-0849
DOI:10.1177/01436244231208078