Development of wide range photon detection system for muonic X-ray spectroscopy

We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition system. The absolute energy accuracy, energy and timing resol...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2023-12
Hauptverfasser: Mizuno, R, Niikura, M, Saito, T Y, Matsuzaki, T, Sakurai, H, Amato, A, Asari, S, Biswas, S, Chiu, I, Gerchow, L, Guguchia, Z, Janka, G, Ninomiya, K, Ritjoho, N, Sato, A, K von Schoeler, Tomono, D, Terada, K, Wang, C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition system. The absolute energy accuracy, energy and timing resolutions, photo-peak efficiency, the performance of the Compton suppressor, and high count rate durability are studied with standard \(\gamma\)-ray sources and in-beam experiment using \(^{27}\mathrm{Al}(p, \gamma){}^{28}\mathrm{Si}\) resonance reaction. The detection system was demonstrated at Paul Scherrer Institute. A calibration method for a photon detector at a muon facility using muonic X-rays of \(^{197}\)Au and \(^{209}\)Bi is proposed.
ISSN:2331-8422